If the Daimler AG versus France air-conditioning refrigerant saga would be a book, this new information would be the chapter when the plot suddenly thickens.
As you all probably know by now, France has banned the sale of the Mercedes-Benz A-Class, B-Class and the CLA on their territory over the models' use of the R134a AC coolant, which will be outlawed by the European Union from 2017 for environmental reasons.
Germany's Federal Motor Transport Authority (KBA) recently issued a report of its findings following the subsequent testing of a number of cars that use the new R1234yf air conditioning coolant, which is set to replace the old R134a.
Their conclusion? The new refrigerant - which has been ostracized by Daimler AG following over 100 in-house test that proved it possesses an increased fire risk during certain types of head-collisions – is more hazardous than the old one, but it doesn't comprise a serious danger.
“Due to the comparisons with the previous refrigerant 134a in Stage 3, one can ascertain that the safety level of cars tends to deteriorate when 1234yf is used,” the KBA report mentioned.
Although the report is kind of in line with France's stance in the matter, looking deeper in the details given it also appears that Daimler AG is not exactly the boy who cried wolf when there wasn't any wolf in sight.
Of the four cars tested by the KBA (A Mercedes-Benz B-Class, A Hyundai i30, Subaru Impreza and an Opel Mokka) one of them burst into flames and also emitted a pretty considerable amount of the highly toxic hydrogen fluoride gas.
According to the report, quoted by Reuters, “non-negligible” amounts of the gas were detected in two of the other cars being crash tested, but the coolant itself only ignited in one test. In other words, for the time being, everyone is right about the matter. A more comprehensive final report will be released in mid-september, while the EU officials will obviously have the final word. Our say? Why don't you check out our editorial to find out a more personal opinion.
Showing posts with label a-gas remtec. Show all posts
Showing posts with label a-gas remtec. Show all posts
Tuesday, August 13, 2013
Tuesday, July 30, 2013
A-Gas RemTec’s Total Solutions Program Provides Complete Cradle-to-Grave Refrigerant Management
BOWLING
GREEN, Ohio --
Founded in 1986, as
RemTec International, A-Gas RemTec, has provided products and services involved
in managing Ozone Depleting Substances (ODS) and substances high in Global
Warming Potential (GWP) on a worldwide basis. The Company’s patented and proprietary
equipment is used to recover and reclaim Halons and their replacement agents
used in the fire protection industry, and also CFCs, HCFCs, and HFCs used in
refrigerant and HVAC applications.
A-Gas RemTec’s
capabilities represent a complete cradle-to-grave refrigerant management
program known as the Total Solutions™ Program. The Total Solutions™ Program
provides the only complete cradle-to-grave refrigerant management service under
one roof. The total integration of services from beginning to end provides many
cost efficiencies that benefit customers.
The Total Solutions™
Program provides customers with access to a full product line of refrigerants,
including supplies of R22 that can be provided throughout the transitional
industry phase-out.. A-Gas, a market leader in the UK, Australia, South Africa,
and now in the U.S., provides a full range of products at competitive prices.
In association with their sister company, Coolgas, they have nationwide
distribution capabilities for any refrigerants that may be needed.
A-Gas RemTec reclaims
used refrigerants using full distillation processing to return mixed
refrigerants to AHRI 700-12 standards. This provides greater cost efficiencies
to customers by utilizing a higher degree of contaminated refrigerants causing fewer
destruction costs and unusable refrigerants. Refrigerants considered
un-reclaimable or unusable are accepted and destroyed at no cost. All unusable
refrigerants are destroyed on-site at their Bowling Green, Ohio facility. A-Gas
RemTec utilizes Plascon, which is plasma arc destruction technology.
Competitive compensation is offered for refrigerants of value that meet purity
criteria. A-Gas RemTec offers a fleet of cylinders and ISO Tanks that can be
shipped to customers to aid in the recovery of refrigerants. Contrastingly, if
a customer has a recovery tank that needs to be refurbished or recertified,
A-Gas RemTec has a Department of Transportation Certified facility in Bowling
Green, Ohio. As an added service, A-Gas RemTec maintains one of only three AHRI-certified
laboratories in the U.S., providing one of the most accurate and integrated
testing facilities for halocarbons. As an EPA Certified Reclamation Company, a
complete disposition report on all materials processed is provided for
customers to file with their EPA records.
Total Solutions™ Program
offers a complete banking system to securely warehouse and manage the inventory
of critical-use gases. A-Gas RemTec has built and managed strategic banking
reserves for the U.S. Department of Defense and a major U.S. aircraft
manufacturer. The Majority stockholder of A-Gas Group, Lloyds Development
Capital (a division of Lloyds Banking Group, the largest financial institution
in the UK), enables A-Gas RemTec the financial strength to meet any project
requirements.
About A-Gas International
A-Gas is an international group of companies with headquarters in the United Kingdom. A-Gas is a market leader in the supply of refrigerants within its core territories in the U.K., South Africa, and Australia, and has state of the art storage, blending, packaging and reclamation facilities in Bristol, Cape Town, and Melbourne. The company is rapidly growing its market share in Asia and the Americas with sales offices in Singapore, Thailand, China and the USA. For more information, visitwww.agas.com.
A-Gas is an international group of companies with headquarters in the United Kingdom. A-Gas is a market leader in the supply of refrigerants within its core territories in the U.K., South Africa, and Australia, and has state of the art storage, blending, packaging and reclamation facilities in Bristol, Cape Town, and Melbourne. The company is rapidly growing its market share in Asia and the Americas with sales offices in Singapore, Thailand, China and the USA. For more information, visitwww.agas.com.
About A-Gas RemTec
For more information, visit www.remtec.net.
For more information, visit www.remtec.net.
New Compliance Association Unites California Offset Project Developers
Stemming from the Navigating the American Carbon World conference in 2012, the newly formed Compliance Offset Developers Association (CODA) seeks to unite project developers and to support an effective cap-and-trade program in California. CODA provides a platform for sharing technical knowledge and ideas as they pertain to the Air Resources Board.
1 July 2013 | The latest cap-and-trade development to come out of California is reflective of the Golden State’s reputation as the prevailing leader in domestic climate policy. The newly-minted Compliance Offset Developers Association (CODA) is an alliance of six project developers – A-GAS RemTec, Camco, Coolgas, Inc, Diversified Pure Chem, Environmental Credit Corp, and Terrapass – working together with regulators and other offset stakeholders to support an effective statewide offset market.
At the 10th anniversary of the Navigating the American Carbon World conference, North America’s largest carbon event, a number of players in California’s offset market recognized the benefits of exchanging ideas and technical know-how related to the Air Resources Board (ARB). Acknowledging ARB’s impact, their own strength in numbers, and a growing need to respond to future technical processes on a collaborative basis, project developers set out to create a forum for technical discussion and knowledge-sharing regarding ARB protocols and the generation of compliance offsets.
As reported by CODA, policies regulating offsets, transparency, and the timely review of project documents are critical aspects for project developers in generating and issuing offsets. An anticipated 200 million offsets will be required by California’s cap-and-trade program by 2020, further highlighting the need for increased capacity through collective efforts such as CODA, according to the group’s members.
Intended to function from a procedural and technical perspective rather than from a political stance, CODA aims to connect project developers to better understand the rules and regulations of the offset market. According to Derek Six, CEO of Environmental Credit Corp, “the project developers involved in CODA face a wide variety of common issues.” The association was formed out of a “desire to see a marketplace that is effective, practical, and efficient,” adds Six.
While CODA is currently only open to project developers that have at least three registered projects under ozone-depleting substances, forestry, or livestock protocols, there may be potential for including project developers involved in other project types in the future.
In reference to prospective protocols such as rice cultivation, coal mine methane, and REDD+, Charles Purshouse, CODA’s elected chairperson, stated, “If approved, we would welcome members developing those projects.” However, for the time being, the “focus is on the drawing board,” as lobbying for REDD+ and other potential protocols “doesn’t fall under the group’s remit,” adds Purshouse.
CODA holds bi-weekly meetings and discussions to formulate strategy. Companies interested in joining CODA can email nick@terrapass.com.
1 July 2013 | The latest cap-and-trade development to come out of California is reflective of the Golden State’s reputation as the prevailing leader in domestic climate policy. The newly-minted Compliance Offset Developers Association (CODA) is an alliance of six project developers – A-GAS RemTec, Camco, Coolgas, Inc, Diversified Pure Chem, Environmental Credit Corp, and Terrapass – working together with regulators and other offset stakeholders to support an effective statewide offset market.
At the 10th anniversary of the Navigating the American Carbon World conference, North America’s largest carbon event, a number of players in California’s offset market recognized the benefits of exchanging ideas and technical know-how related to the Air Resources Board (ARB). Acknowledging ARB’s impact, their own strength in numbers, and a growing need to respond to future technical processes on a collaborative basis, project developers set out to create a forum for technical discussion and knowledge-sharing regarding ARB protocols and the generation of compliance offsets.
As reported by CODA, policies regulating offsets, transparency, and the timely review of project documents are critical aspects for project developers in generating and issuing offsets. An anticipated 200 million offsets will be required by California’s cap-and-trade program by 2020, further highlighting the need for increased capacity through collective efforts such as CODA, according to the group’s members.
Intended to function from a procedural and technical perspective rather than from a political stance, CODA aims to connect project developers to better understand the rules and regulations of the offset market. According to Derek Six, CEO of Environmental Credit Corp, “the project developers involved in CODA face a wide variety of common issues.” The association was formed out of a “desire to see a marketplace that is effective, practical, and efficient,” adds Six.
While CODA is currently only open to project developers that have at least three registered projects under ozone-depleting substances, forestry, or livestock protocols, there may be potential for including project developers involved in other project types in the future.
In reference to prospective protocols such as rice cultivation, coal mine methane, and REDD+, Charles Purshouse, CODA’s elected chairperson, stated, “If approved, we would welcome members developing those projects.” However, for the time being, the “focus is on the drawing board,” as lobbying for REDD+ and other potential protocols “doesn’t fall under the group’s remit,” adds Purshouse.
CODA holds bi-weekly meetings and discussions to formulate strategy. Companies interested in joining CODA can email nick@terrapass.com.
Tuesday, July 2, 2013
EPA Warns Against Use of Refrigerant Substitutes That Pose Fire and Explosion Risk
FOR IMMEDIATE RELEASE
July 1, 2013
July 1, 2013
WASHINGTON – The U.S. Environmental Protection Agency (EPA) is warning homeowners, propane manufacturers and sellers, home improvement contractors and air conditioning technicians of potential safety hazards related to the use of propane or other unapproved refrigerants in home air conditioning systems.
EPA is currently investigating instances where propane has been marketed and used as a substitute for HCFC-22 (R-22), a refrigerant that is widely used in home air conditioning systems.
Home air conditioning systems are not designed to handle propane or other similar flammable refrigerants. The use of these substances poses a potential fire or explosion hazard for homeowners and service technicians.
EPA is aware of incidents that have occurred both overseas and in the U.S. where individuals have been injured as a result of the use of propane and other unapproved refrigerants in air conditioning systems. We are investigating and will take enforcement actions where appropriate. Other names for these unapproved refrigerants include R-290, 22a, 22-A, R-22a, HC-22a, and CARE 40.
At this time, EPA has not approved the use of propane refrigerant or other hydrocarbon refrigerants in any type of air conditioner. Homeowners and technicians are strongly recommended to limit use of propane or other hydrocarbons to only those appliances specifically designed for these substances and that are properly marked to alert technicians that the equipment contains a flammable substance. EPA has approved the use of propane as a substitute refrigerant for R-22 in industrial process refrigeration systems and in new, stand-alone retail food refrigerators and freezers that are specifically designed to use flammable hydrocarbon refrigerants.
R-22 is being phased out of production and importation under the Montreal Protocol, an environmental treaty ratified by every country in the world designed to reduce and eventually eliminate the use of ozone depleting substances. EPA’s Significant New Alternatives Policy (SNAP) Program has already listed numerous refrigerants with improved environmental, health and safety profiles and continues to evaluate other refrigerants that can be used to replace R-22 and other ozone-depleting substances.
More information about the EPA’s SNAP program: http://www.epa.gov/ozone/snap/
More information about R-22a and alternatives for air conditioning: http://www.epa.gov/ozone/snap/r22a.html
Monday, June 17, 2013
Renewed interest in HC heat pumps in Europe – exclusive interview with D. Colbourne
The increasing availability in Europe of optimised R290 compressors for heat pumps is reviving interest in the technology. During the UNIDO ATMOsphere Technology Summit, hydrocarbons21.com interviewed Mr. Daniel Colbourne, Consultant at Re-phridge, about the historical development of hydrocarbon (HC) heat pumps and the current state of play in Europe.
hydrocarbons21.com: In the 1990s there were several hydrocarbon-based heat pump products for domestic application in the EU market, which subsequently disappeared. What in your view might have caused this?
Daniel Colbourne: There were many hydrocarbon (HC) heat pump products on the European market; Austria, Switzerland, Scandinavia and Germany, mainly from small and medium sized producers. But the EU Pressure Equipment Directive (PED) was introduced which basically states that the components and piping in the refrigeration system must be designed, tested and approved for that particular refrigerant (or refrigerant “group”). The PED requirements for flammable refrigerants are one level above those for the non-flammable, low toxicity fluid “group”, which includes refrigerants like R22.
Previously many companies were taking R22 compressors and adapting them for use with R290. So when the PED came into force it essentially meant that they could no longer utilise those R22 compressors; i.e., they could only use R290 compressors for R290. At the time there were no manufacturers producing the right type of R290 compressors and, since in order to certify compressors for R290, additional approval processes are necessary (which in some cases are costly), the size of the market was evidently not sufficient for manufacturers to justify it. For example, the person that is welding the compressors has got to have a higher level of certification, which implies additional investments for the compressor manufacturers.
So the heat pump manufacturers apparently had little choice, all they could do was to switch to an alternative which was not a flammable refrigerant. I would say that was the main reason for the decline. Given the extensive literature demonstrating the comparatively higher efficiency of R290 and the excellent safety record, it was not performance or hazardous aspects that were responsible.
A number of manufacturers continued with some R290 models (and still do today) in particular for smaller capacity units where R290 hermetic compressors normally used for commercial refrigeration are suitable. Nonetheless, this represents a relatively small portion of the market.
hydrocarbons21.com: In terms of performance and reliability, how were these R290 products performing?
Colbourne: With regards to reliability, when R22 compressors were initially used there were some problems. However, a study presented by a major German player on the development of their R290 heat pumps in 1999 stated that after optimisation of the compressor oil, the reliability of their R290 heat pumps was better than that of their R22 heat pumps. Of course, many companies are currently selling R290 heat pumps, which would not be the case were there reliability issues.
Throughout that period there were many studies published on the efficiency of hydrocarbons in heat pumps and most of them said that R290 performance was at least as good, typically much better than the other alternatives (for space heating purposes). Both the large volume of technical literature and publications from different manufacturers support this. Furthermore, when considering the thermophysical properties of HCs, it is fairly obvious; not only do the thermodynamic properties demonstrate this but also the excellent viscosity and thermal conductivity infers better component performance than most other fluorinated alternatives.
hydrocarbons21.com: More recently do you see a renewed interest in the use of hydrocarbons in heat pumps by European manufacturers?
Colbourne: In general we can see increasing pressure to use heat pumps in Europe as they are seen as a means for accelerating CO2 emission reduction. Within this context it seems rather daft to not use low-GWP refrigerants or particularly natural refrigerants for those types of products where they can be used. There are a fairly large number of manufacturers within Europe (but also Australia and China) that are currently using HCs (as well as other natural refrigerants). In this respect there is increasing interest in some quarters, but of course others are also resisting.
The safety issue is surely already addressed, since relevant safety regulations and standards are available and have been for many years.
hydrocarbons21.com: Heat pump manufacturers often state that the reason they do not offer HC-based heat pumps is that they cannot find optimised HC compressors or other components for the purpose. What would you recommend to the industry for overcoming this barrier?
Colbourne: On the compressor side, at least two major compressor manufacturers are now producing compressors specifically designed and optimised for R290 heat pump systems, implying that this barrier is now becoming resolved. Moreover, there are several companies that make other components, such as controls for hydrocarbons that can be used in heat pumps. These enterprises obviously see that there is a market and they would not invest large sums in the technology unless they had confidence in it.
hydrocarbons21.com: In the 1990s there were several hydrocarbon-based heat pump products for domestic application in the EU market, which subsequently disappeared. What in your view might have caused this?
Daniel Colbourne: There were many hydrocarbon (HC) heat pump products on the European market; Austria, Switzerland, Scandinavia and Germany, mainly from small and medium sized producers. But the EU Pressure Equipment Directive (PED) was introduced which basically states that the components and piping in the refrigeration system must be designed, tested and approved for that particular refrigerant (or refrigerant “group”). The PED requirements for flammable refrigerants are one level above those for the non-flammable, low toxicity fluid “group”, which includes refrigerants like R22.
Previously many companies were taking R22 compressors and adapting them for use with R290. So when the PED came into force it essentially meant that they could no longer utilise those R22 compressors; i.e., they could only use R290 compressors for R290. At the time there were no manufacturers producing the right type of R290 compressors and, since in order to certify compressors for R290, additional approval processes are necessary (which in some cases are costly), the size of the market was evidently not sufficient for manufacturers to justify it. For example, the person that is welding the compressors has got to have a higher level of certification, which implies additional investments for the compressor manufacturers.
So the heat pump manufacturers apparently had little choice, all they could do was to switch to an alternative which was not a flammable refrigerant. I would say that was the main reason for the decline. Given the extensive literature demonstrating the comparatively higher efficiency of R290 and the excellent safety record, it was not performance or hazardous aspects that were responsible.
A number of manufacturers continued with some R290 models (and still do today) in particular for smaller capacity units where R290 hermetic compressors normally used for commercial refrigeration are suitable. Nonetheless, this represents a relatively small portion of the market.
hydrocarbons21.com: In terms of performance and reliability, how were these R290 products performing?
Colbourne: With regards to reliability, when R22 compressors were initially used there were some problems. However, a study presented by a major German player on the development of their R290 heat pumps in 1999 stated that after optimisation of the compressor oil, the reliability of their R290 heat pumps was better than that of their R22 heat pumps. Of course, many companies are currently selling R290 heat pumps, which would not be the case were there reliability issues.
Throughout that period there were many studies published on the efficiency of hydrocarbons in heat pumps and most of them said that R290 performance was at least as good, typically much better than the other alternatives (for space heating purposes). Both the large volume of technical literature and publications from different manufacturers support this. Furthermore, when considering the thermophysical properties of HCs, it is fairly obvious; not only do the thermodynamic properties demonstrate this but also the excellent viscosity and thermal conductivity infers better component performance than most other fluorinated alternatives.
hydrocarbons21.com: More recently do you see a renewed interest in the use of hydrocarbons in heat pumps by European manufacturers?
Colbourne: In general we can see increasing pressure to use heat pumps in Europe as they are seen as a means for accelerating CO2 emission reduction. Within this context it seems rather daft to not use low-GWP refrigerants or particularly natural refrigerants for those types of products where they can be used. There are a fairly large number of manufacturers within Europe (but also Australia and China) that are currently using HCs (as well as other natural refrigerants). In this respect there is increasing interest in some quarters, but of course others are also resisting.
The safety issue is surely already addressed, since relevant safety regulations and standards are available and have been for many years.
hydrocarbons21.com: Heat pump manufacturers often state that the reason they do not offer HC-based heat pumps is that they cannot find optimised HC compressors or other components for the purpose. What would you recommend to the industry for overcoming this barrier?
Colbourne: On the compressor side, at least two major compressor manufacturers are now producing compressors specifically designed and optimised for R290 heat pump systems, implying that this barrier is now becoming resolved. Moreover, there are several companies that make other components, such as controls for hydrocarbons that can be used in heat pumps. These enterprises obviously see that there is a market and they would not invest large sums in the technology unless they had confidence in it.
Beware of Flammable R-22a Refrigerants!
June 12, 2013
With the phaseout of the refrigerant R-22, dangerous replacements are surfacing. Steer clear of purchasing highly flammable products sold that are listed in a form of 22a Refrigerant, as the gas can burn or even explode when in contact with an ignition source.There is great concern over the flammability of these products, when used as a refrigerant in air conditioning equipment. The U.S. Environmental Protection Agency (EPA) has a Significant New Alternatives Policy (SNAP) that maintains lists of acceptable refrigerants in listed applications. EPA has issued some Frequently Asked Questions (FAQ’s) regarding these R-22a products, click here to read these FAQ’s.
These products could pose significant safety risks to homeowners and technicians. Unknowing homeowners who have used this product may have created an exposure to fire or explosion should a leak be present in the home. Technicians that have not been informed of the use of these products face similar risks in that their service equipment is not designed for these products. Inadvertent mixing of recovered gases may contaminate a contractor’s bulk recovery cylinder forcing disposal of the product in place of reclaiming.
There are many approved replacement refrigerants being marketed today; contractors should carefully consider the products they wish to use. For a list of EPA approved alternate refrigerants for residential air conditioning, click here.
Remember, it is illegal for anyone to intentionally mix refrigerants in equipment or to intentionally vent refrigerant to the atmosphere. Use alternate refrigerants wisely; do not top off a system with an alternate refrigerant.
Thursday, June 13, 2013
Coming to America
U.K.'s A-Gas Plans Expansion Into North America
A-Gas’s acquisitions in the U.S. will set it up for a significant expansion into North America, including the international rollout of its refrigerant reclamation technology.Acquiring Assets
Reclamation Technology
Industry Encourages Cap Use on Refrigerants
Industry Encourages Cap Use on Refrigerants
Recent Deaths Demonstrate Dangers of Huffing R-22
By Peter Powell
This past March, Kristal Salcido, a 12-year-old seventh grader in
Victorville, Calif., inhaled HCFC-22 from an air conditioning unit in the
backyard of her grandmother’s home. She was later found passed out on the
bathroom floor. Rushed to the emergency room, Salcido was pronounced brain dead.
Four days later, her family decided to take her off life support.
She had used the R-22 in a ritual called huffing — the intentional inhalation of chemical vapors to attain a mental high or euphoric effect.
Refrigerants such as CFCs, HCFCs, HFCs, and propane are just part of that chemical basket of inhalants. Others are gasoline, paint thinners, nail polish, and nitrous oxide. According to the website www.inhalants.org, one in five students has inhaled a chemical to get high by the eighth grade.
“People really don’t realize how dangerous this is,” said Dr. Craig Sanford, Tulsa, Okla., in a news report broadcast by NewsOn6. “Inhaling this substance prevents the body from getting oxygen and you can get frostbite from it, inside the tissues of your nose, mouth, and face.”
Postoian said that he’s serviced a number of condensing units where the refrigerant had suspiciously been used up.
That “missing refrigerant” aspect was echoed by Ryan Rentmeister, who owns Rentmeister Total Home Service of Salt Lake City. A few years ago in his hometown, people were turning on their air conditioners, but the machines were failing to provide cool air, due to absent refrigerant. “We’ve had four cases in the last week,” he said, suspecting huffing as the cause.
Ronda Szymanski of Advanced Air and Refrigeration Inc., Fort Myers, Fla., said a telltale sign is when service techs find a butter knife laying next to a central air conditioning condenser that has been depleted of refrigerant, with its service port visibly damaged.
Code requirements have been in place since 2009, but these requirements need to be codified by each state, said Gerry Spanger, director of HVACR engineered products for Rectorseal Corp.
So far, at least five states have adopted the codes, said Spanger. However, limiting more widespread acceptance, the codes are only related to new construction. He said eventually the codes will extend into retrofits and existing buildings. “It is not a question of ‘no, this won’t happen.’ It is just a question of how long it takes,” said Spanger.
Once state codes are in place, inspectors cannot sign off on a job until the locking caps are in place.
“The products are a must for companies and technicians to comply with local codes as well as liability concerns connected with refrigerants,” said Oscar Lopez, vice president of sales for JB Industries Inc., Aurora, Ill.
Spanger said that even as all the regulatory aspects eventually fall into place, there is still the possibility of abuse within the HVACR sector. He said he’d even heard of contractors buying the caps, locking them in place when required, and then removing them after an inspection for use in the next project.
“They don’t understand they are laying themselves open to liabilities,” he said.
He also said that even though the caps can only be sold to contractors who are U.S. Environmental Protection Agency (EPA)-certified to handle refrigerants, he had heard of instances of some wholesalers and contractors who sell the caps on websites, even though they may not be able to verify the certification status of the purchaser.
According to Jon Melchi, director of government affairs for Heating, Air-conditioning & Refrigeration Distributors International (HARDI), “Wholesalers and suppliers strongly believe that these products should not be available online. They should only be sold to licensed contractors. As an industry we must be diligent in making sure that the entire channel is aware of best practices regarding these products.”
For example, this past February, Rectorseal Corp. introduced its GasGuard™, a tamper-resistant locking valve cap designed to help prevent refrigerant theft, leaks, and huffing. It screws and locks onto threaded refrigerant Schraeder valves.
“GasGuard restricts unauthorized access because it can only be installed or removed with a unique matching proprietary socket tool,” said Jerry Tomasello, director of marketing for RectorSeal. “It cannot be removed with a core remover or Allen wrench.”
JB’s Lopez also noted that his company is launching a new American-made refrigerant safety cap with greater security under the brand name The Shield.
“SAFE is still actively pushing it and Dominion Service is currently doing a public service campaign in the Hampton Roads, Va., area,” he said. “Our Richmond division has had huge success with the program but Hampton Roads has been a little slower to catch on. We are working on fixing that.
“We are currently installing 10-15 caps each week. We’re confident that number will increase significantly as the summer season hits.”
She had used the R-22 in a ritual called huffing — the intentional inhalation of chemical vapors to attain a mental high or euphoric effect.
Refrigerants such as CFCs, HCFCs, HFCs, and propane are just part of that chemical basket of inhalants. Others are gasoline, paint thinners, nail polish, and nitrous oxide. According to the website www.inhalants.org, one in five students has inhaled a chemical to get high by the eighth grade.
The Hazards of Huffing
In the case of the R-22, “When you inhale it, it kills your brain cells — that’s all,” said Ron Postoian, president of AC Plus Heating & Air of Hesperia, Calif., who was interviewed by television station KTLA for its story on a recent huffing fatality in his home state.“People really don’t realize how dangerous this is,” said Dr. Craig Sanford, Tulsa, Okla., in a news report broadcast by NewsOn6. “Inhaling this substance prevents the body from getting oxygen and you can get frostbite from it, inside the tissues of your nose, mouth, and face.”
Postoian said that he’s serviced a number of condensing units where the refrigerant had suspiciously been used up.
That “missing refrigerant” aspect was echoed by Ryan Rentmeister, who owns Rentmeister Total Home Service of Salt Lake City. A few years ago in his hometown, people were turning on their air conditioners, but the machines were failing to provide cool air, due to absent refrigerant. “We’ve had four cases in the last week,” he said, suspecting huffing as the cause.
Ronda Szymanski of Advanced Air and Refrigeration Inc., Fort Myers, Fla., said a telltale sign is when service techs find a butter knife laying next to a central air conditioning condenser that has been depleted of refrigerant, with its service port visibly damaged.
Curbing the Problem
Regulators and many within the HVACR industry have been working hard to get a handle on this deadly situation. Both the International Mechanical Code 1101.10 and the International Residential Code M1411.6 have mandated that “refrigerant-circuit access ports located outdoors shall be fitted with locking-type tamper-resistant caps.”Code requirements have been in place since 2009, but these requirements need to be codified by each state, said Gerry Spanger, director of HVACR engineered products for Rectorseal Corp.
So far, at least five states have adopted the codes, said Spanger. However, limiting more widespread acceptance, the codes are only related to new construction. He said eventually the codes will extend into retrofits and existing buildings. “It is not a question of ‘no, this won’t happen.’ It is just a question of how long it takes,” said Spanger.
Once state codes are in place, inspectors cannot sign off on a job until the locking caps are in place.
“The products are a must for companies and technicians to comply with local codes as well as liability concerns connected with refrigerants,” said Oscar Lopez, vice president of sales for JB Industries Inc., Aurora, Ill.
Spanger said that even as all the regulatory aspects eventually fall into place, there is still the possibility of abuse within the HVACR sector. He said he’d even heard of contractors buying the caps, locking them in place when required, and then removing them after an inspection for use in the next project.
“They don’t understand they are laying themselves open to liabilities,” he said.
He also said that even though the caps can only be sold to contractors who are U.S. Environmental Protection Agency (EPA)-certified to handle refrigerants, he had heard of instances of some wholesalers and contractors who sell the caps on websites, even though they may not be able to verify the certification status of the purchaser.
According to Jon Melchi, director of government affairs for Heating, Air-conditioning & Refrigeration Distributors International (HARDI), “Wholesalers and suppliers strongly believe that these products should not be available online. They should only be sold to licensed contractors. As an industry we must be diligent in making sure that the entire channel is aware of best practices regarding these products.”
Locked and Loaded
While controlling huffing remains a key aspect of locking caps, the devices have long been offered in the HVACR distribution channel for a number of applications. Even as regulations move toward the requirement of locking caps, the devices themselves are being fine tuned.For example, this past February, Rectorseal Corp. introduced its GasGuard™, a tamper-resistant locking valve cap designed to help prevent refrigerant theft, leaks, and huffing. It screws and locks onto threaded refrigerant Schraeder valves.
“GasGuard restricts unauthorized access because it can only be installed or removed with a unique matching proprietary socket tool,” said Jerry Tomasello, director of marketing for RectorSeal. “It cannot be removed with a core remover or Allen wrench.”
JB’s Lopez also noted that his company is launching a new American-made refrigerant safety cap with greater security under the brand name The Shield.
Contractor Support
Numerous contractors, including Chase Tunnell, president, Dominion Service, Richmond, Va., are strong advocates of locking caps. For a number of years, Tunnell has been involved with the Substance Abuse Free Environment (SAFE) program, which encourages the use of locking caps.“SAFE is still actively pushing it and Dominion Service is currently doing a public service campaign in the Hampton Roads, Va., area,” he said. “Our Richmond division has had huge success with the program but Hampton Roads has been a little slower to catch on. We are working on fixing that.
“We are currently installing 10-15 caps each week. We’re confident that number will increase significantly as the summer season hits.”
Counting down to the ban on R22
As the months pass towards the total ban on the use of R22 for servicing air-conditioning equipment, Kevin Groves of Ergro gives his perspective.
The final removal of the HCFC refrigerant R22 from the world’s air conditioning systems has long been heralded and is now upon us here in the UK. Manufacturers of equipment have not included it in new systems since 2003. In 2010 the use of virgin R22 refrigerant was banned, and systems can only now be serviced utilising reclaimed refrigerant for maintenance. Now the final date in the legislative removal of recycled R22 because of its ozone-depleting properties is near. On 1 January 2015, the use of recycled R22 refrigerant will be banned in the EU.
Practically speaking, where R22 refrigerant is in use, there are two main options to make an air-conditioning system serviceable after the ban comes into force. One option is to convert the existing system to enable it to operate using a legal but often less efficient refrigerant or replacing part of or the entire system.
There are two main routes to a conversion solution.
In some cases it will be possible to make a few modifications to the system, such as replacing some gaskets and the oil, which will enable it to run on a new refrigerant such as R422D. This is known as the drop-in refrigerant option, which, in most cases, will lead to a reduction in cooling capacity and increased running costs.
Where another refrigerant cannot be dropped in, there may be the potential to convert the system by installing new fan coils or condensers whilst still retaining much of the building’s existing internal infrastructure such as piping. As well as increasing system capacity, conversion is likely to improve the overall efficiency of a system through the use of modern refrigerants (except when using the drop-in option).
Both solutions are, however, heavily dependent on site, installation conditions and age of the plant.
Systems not suitable for conversion will need to be replaced. Despite the higher installation costs, replacement can lead to greater system efficiencies, lower maintenance requirements and reduced operating costs.
For building-services engineers, the effect of the legislation is likely to mean that air conditioning will take centre stage in many of their operations in the coming years. It’s important that the engineering community understands what is business-critical air conditioning and impresses the importance of preparedness upon facilities managers and business leaders.
Who should act and when, what market forces and liabilities are involved and why it’s becoming the most important news in air conditioning may not be immediately obvious to many business leaders and even facilities managers. In fact, many people who could be affected most acutely won’t even know if R22 is used in their air conditioning or even realise they are responsible for the air conditioning in the spaces they occupy.
At a recent summit in London, held at the Royal Society of Medicine, Ergro assembled a panel of experts to answer some of these questions and to raise awareness of the issues surrounding the ban of R22.
The panel introduced the subject from their various perspectives and took questions from an invited audience comprising building managers, consultants, architects and business leaders.
There were several points upon which the panel was in complete agreement, chief among which was the need for people to gain the knowledge required to properly evaluate their position in relation to a date which, while it seems distant, taken in the context of the financial cycles and business-critical nature of the systems involved, is actually almost upon us.
I represented Ergro on the panel to offer the insight of a contracting engineer who works with air conditioning for skyscrapers, manufacturing, data centres and offices. Also on the panel were representatives of leading air-conditioning manufacturers Mitsubishi Electric and Daikin, legal and liability expertise from property law firm Taylor Wessing and chartered accountants and chartered tax advisors LB Group.
One question concerned the subtleties of supply and demand of the refrigerant itself. R22 is presently trading at around £30 per kilo in the UK, and this price is rising all of the time. When considering the fact that it will become illegal to buy or sell from the end of 2014 it would seem likely that the upward trend in its value will continue.
And what about installing new equipment? If it’s critical to the business that maintenance is possible and downtime avoidable, as it is in many of the instances where an estimated 750 000 systems using R22 exist, then a lot of companies will be looking to replace equipment at around the same time.
Needless to say, where demand outstrips supply in terms of the expertise to fit new systems, there are likely to be delays that could cause unnecessary risk to business continuity.
While it does seem to be a little way off, the R22 refrigerant ban will very soon make its presence felt across the business community. From now and for the next 18 months and beyond, building-services engineers will be at the heart of making business-critical systems compliant and serviceable into the future. But the whole facilities management and building services industry must come together with manufacturers and business services to help the business community to understand how the changes will affect them. Knowledge is power, and a full evaluation of existing systems will equip business leaders with the knowledge to make the right decisions to get ahead of the ban. More information and a countdown to the ban clock is available at the link below.
Kevin Groves is group operations director with Ergro
- See more at: http://www.modbs.co.uk/news/fullstory.php/aid/11893/Counting_down_to_the_ban_on_R22.html#sthash.HbKs8XtY.dpuf
The final removal of the HCFC refrigerant R22 from the world’s air conditioning systems has long been heralded and is now upon us here in the UK. Manufacturers of equipment have not included it in new systems since 2003. In 2010 the use of virgin R22 refrigerant was banned, and systems can only now be serviced utilising reclaimed refrigerant for maintenance. Now the final date in the legislative removal of recycled R22 because of its ozone-depleting properties is near. On 1 January 2015, the use of recycled R22 refrigerant will be banned in the EU.
Practically speaking, where R22 refrigerant is in use, there are two main options to make an air-conditioning system serviceable after the ban comes into force. One option is to convert the existing system to enable it to operate using a legal but often less efficient refrigerant or replacing part of or the entire system.
There are two main routes to a conversion solution.
In some cases it will be possible to make a few modifications to the system, such as replacing some gaskets and the oil, which will enable it to run on a new refrigerant such as R422D. This is known as the drop-in refrigerant option, which, in most cases, will lead to a reduction in cooling capacity and increased running costs.
Where another refrigerant cannot be dropped in, there may be the potential to convert the system by installing new fan coils or condensers whilst still retaining much of the building’s existing internal infrastructure such as piping. As well as increasing system capacity, conversion is likely to improve the overall efficiency of a system through the use of modern refrigerants (except when using the drop-in option).
Both solutions are, however, heavily dependent on site, installation conditions and age of the plant.
Systems not suitable for conversion will need to be replaced. Despite the higher installation costs, replacement can lead to greater system efficiencies, lower maintenance requirements and reduced operating costs.
For building-services engineers, the effect of the legislation is likely to mean that air conditioning will take centre stage in many of their operations in the coming years. It’s important that the engineering community understands what is business-critical air conditioning and impresses the importance of preparedness upon facilities managers and business leaders.
Who should act and when, what market forces and liabilities are involved and why it’s becoming the most important news in air conditioning may not be immediately obvious to many business leaders and even facilities managers. In fact, many people who could be affected most acutely won’t even know if R22 is used in their air conditioning or even realise they are responsible for the air conditioning in the spaces they occupy.
At a recent summit in London, held at the Royal Society of Medicine, Ergro assembled a panel of experts to answer some of these questions and to raise awareness of the issues surrounding the ban of R22.
The panel introduced the subject from their various perspectives and took questions from an invited audience comprising building managers, consultants, architects and business leaders.
There were several points upon which the panel was in complete agreement, chief among which was the need for people to gain the knowledge required to properly evaluate their position in relation to a date which, while it seems distant, taken in the context of the financial cycles and business-critical nature of the systems involved, is actually almost upon us.
I represented Ergro on the panel to offer the insight of a contracting engineer who works with air conditioning for skyscrapers, manufacturing, data centres and offices. Also on the panel were representatives of leading air-conditioning manufacturers Mitsubishi Electric and Daikin, legal and liability expertise from property law firm Taylor Wessing and chartered accountants and chartered tax advisors LB Group.
One question concerned the subtleties of supply and demand of the refrigerant itself. R22 is presently trading at around £30 per kilo in the UK, and this price is rising all of the time. When considering the fact that it will become illegal to buy or sell from the end of 2014 it would seem likely that the upward trend in its value will continue.
And what about installing new equipment? If it’s critical to the business that maintenance is possible and downtime avoidable, as it is in many of the instances where an estimated 750 000 systems using R22 exist, then a lot of companies will be looking to replace equipment at around the same time.
Needless to say, where demand outstrips supply in terms of the expertise to fit new systems, there are likely to be delays that could cause unnecessary risk to business continuity.
While it does seem to be a little way off, the R22 refrigerant ban will very soon make its presence felt across the business community. From now and for the next 18 months and beyond, building-services engineers will be at the heart of making business-critical systems compliant and serviceable into the future. But the whole facilities management and building services industry must come together with manufacturers and business services to help the business community to understand how the changes will affect them. Knowledge is power, and a full evaluation of existing systems will equip business leaders with the knowledge to make the right decisions to get ahead of the ban. More information and a countdown to the ban clock is available at the link below.
Kevin Groves is group operations director with Ergro
- See more at: http://www.modbs.co.uk/news/fullstory.php/aid/11893/Counting_down_to_the_ban_on_R22.html#sthash.HbKs8XtY.dpuf
Update: Car engineers pour cold water on Daimler refrigerant fire claims
29 April 2013 | By Andrew Gaved
The CRP was established to examine Mercedes owner Daimler’s claims that HFO 1234yf ignited in a staged head-on collision, whereas the previous refrigerant R134a, outlawed by the Mobile Air Conditioning directive, did not.
In the wake of lurid claims about the risk of flammability in the UK tabloid press, the SAE said CRP team members had again concluded that the refrigerant release testing conducted by Daimler is unrealistic, following numerous additional tests of various types to study ignition of an HFO 1234yf leak in a crash-damaged vehicle.
In another strongly worded statement, SAE said Daimler’s test “is not an appropriate test to verify the safety of refrigerant applications in vehicles. The Daimler testing did not include any actual vehicle collisions or the mitigating factors that occur in an actual collision.”
It said these factors include the quenching effect of front end compartment deformation, the extinguishing effect of steam released due to radiator breakage, and dispersion of the refrigerant from the condenser outside the engine compartment.
“Daimler’s refrigerant release apparatus and nozzle does not represent actual crash-damaged refrigerant lines, and was found to be artificial.”
The report was welcomed by Honeywell Fluorine Products, the manufacturer of the HFO, which emphasised that even those German manufacturers which have indicated they are in favour of using CO2 in the future cars had not found anything unsafe about the HFO.
Honeywell European managing director Paul Sanders said: “Pretty much all of the car industry has said publicly it can use 1234yf safely, including all members of the [German carmakers group] VDA, apart from Daimler. Opel had its test programme undertaken by engineering body TUV (above), which is globally respected.”
Following the report, Mr Sanders said Honeywell was now calling for the European Commission to censure Daimler for continuing to defy the MAC Directive. If strictly applied, the EC could forbid the registering of non-compliant cars, such as the Mercedes A and B class models which are still being produced with R134a, in contravention of the directive.
He said: “All we can ask is that the law is adhered to. The MAC directive is unequivocal that non-compliant cars should not be registered. The car industry has had seven years to make a compliant vehicle. HFO 1234yf is available today, it meets the MAC directive and it is cost-effective.”
Mr Sanders also claimed that Daimler’s preferred refrigerant carbon dioxide – which it has asked the EC for more time to develop – is not as environmentally friendly as HFO 1234yf across the lifetime of a vehicle.
He said: “CO2 is a smokescreen and it is three to five years away at best. As it is an asphyxiant it would need significant changes to car designs and the service charges would be higher, since if it was to leak, it would all leak at once.”
He warned that the Commission needed to take action against Daimler or risk appearing ineffectual: “It sets a dangerous precedent for the forthcoming F-Gas regulations if one company is allowed to go its own way and flout the law. Allegedly Daimler is saving 50 euros a car for not using 1234yf. It is not a safety issue, it is a political issue.”
Car engineering research group SAE International has reported the conclusions of its extensive analysis of HFO 1234yf, calling the refrigerant “safe and effective to use in automotive applications” - free to view, simply register
The team on SAE’s Cooperative Research Programme, comprising most car manufacturers from Ford to Renault to Toyota, concluded that “the risk of passenger exposure to a vehicle fire associated with this refrigerant is exceptionally remote”.The CRP was established to examine Mercedes owner Daimler’s claims that HFO 1234yf ignited in a staged head-on collision, whereas the previous refrigerant R134a, outlawed by the Mobile Air Conditioning directive, did not.
In the wake of lurid claims about the risk of flammability in the UK tabloid press, the SAE said CRP team members had again concluded that the refrigerant release testing conducted by Daimler is unrealistic, following numerous additional tests of various types to study ignition of an HFO 1234yf leak in a crash-damaged vehicle.
In another strongly worded statement, SAE said Daimler’s test “is not an appropriate test to verify the safety of refrigerant applications in vehicles. The Daimler testing did not include any actual vehicle collisions or the mitigating factors that occur in an actual collision.”
It said these factors include the quenching effect of front end compartment deformation, the extinguishing effect of steam released due to radiator breakage, and dispersion of the refrigerant from the condenser outside the engine compartment.
“Daimler’s refrigerant release apparatus and nozzle does not represent actual crash-damaged refrigerant lines, and was found to be artificial.”
The report was welcomed by Honeywell Fluorine Products, the manufacturer of the HFO, which emphasised that even those German manufacturers which have indicated they are in favour of using CO2 in the future cars had not found anything unsafe about the HFO.
Honeywell European managing director Paul Sanders said: “Pretty much all of the car industry has said publicly it can use 1234yf safely, including all members of the [German carmakers group] VDA, apart from Daimler. Opel had its test programme undertaken by engineering body TUV (above), which is globally respected.”
Following the report, Mr Sanders said Honeywell was now calling for the European Commission to censure Daimler for continuing to defy the MAC Directive. If strictly applied, the EC could forbid the registering of non-compliant cars, such as the Mercedes A and B class models which are still being produced with R134a, in contravention of the directive.
He said: “All we can ask is that the law is adhered to. The MAC directive is unequivocal that non-compliant cars should not be registered. The car industry has had seven years to make a compliant vehicle. HFO 1234yf is available today, it meets the MAC directive and it is cost-effective.”
Mr Sanders also claimed that Daimler’s preferred refrigerant carbon dioxide – which it has asked the EC for more time to develop – is not as environmentally friendly as HFO 1234yf across the lifetime of a vehicle.
He said: “CO2 is a smokescreen and it is three to five years away at best. As it is an asphyxiant it would need significant changes to car designs and the service charges would be higher, since if it was to leak, it would all leak at once.”
He warned that the Commission needed to take action against Daimler or risk appearing ineffectual: “It sets a dangerous precedent for the forthcoming F-Gas regulations if one company is allowed to go its own way and flout the law. Allegedly Daimler is saving 50 euros a car for not using 1234yf. It is not a safety issue, it is a political issue.”
FLUOROCARBON INDUSTRY CONTRIBUTES $158 BILLION TO U.S. ECONOMY
WASHINGTON,
D.C. - The Alliance for Responsible Atmospheric Policy (Alliance), an industry
coalition, today released a report detailing that the U.S. fluorocarbon
industry’s total annual sale of goods and services amounts to $158
billion.
“The
role of fluorocarbons in both stratospheric ozone protection and global climate
change has generated a need for governments, policymakers, and scientists to
understand the scope of the industry, usage patterns, business sector volumes,
and their value to society,” stated Dave Stirpe, Alliance Executive Director.
The
products analyzed by the study include hydrochlorofluorocarbons (HCFCs),
hydrofluorocarbons (HFCs), and the products that contain or are manufactured
with the compounds such as air conditioning, refrigeration, foam insulation,
and metered dose inhalers. The value to the U.S. economy is rounded out
by the value of the wholesale, installation, and maintenance activities – as
well as recovery, recycling, reclamation, and destruction of used refrigerants
and foam blowing agents.
“These
compounds and the products utilizing HCFCs and HFCs contribute greatly to the
quality of life while at the same time minimizing impacts on the stratospheric
ozone layer and the climate,” stated Stirpe. “Over the years, industry
has improved technology in food-preserving refrigeration, air conditioning in buildings
and motor vehicles, insulation systems, and other products. Businesses
are working to make transitions to compounds with more environmental protection
while continuing the important attributes contained in fluorocarbons such as
energy efficiency, low toxicity, and non-flammability,” Stirpe said.
The
39-page study, written by Joseph M. Steed, JMS Consulting, uses public data and
industry information to assess the broadly-defined US fluorocarbon
industry. A copy of the study is available on the Alliance website at www.alliancepolicy.org.
For 32
years the Alliance has coordinated industry participation in the development of
responsible international and U.S. government policies regarding ozone protection
and climate change. It is composed of manufacturers and businesses that
rely on fluorocarbons.
##
Dave Stirpe
Executive Director
Alliance for Responsible Atmospheric Policy
2111 Wilson Blvd., 8th Floor
Arlington, VA 22201
phone: (703) 243-0344
Executive Director
Alliance for Responsible Atmospheric Policy
2111 Wilson Blvd., 8th Floor
Arlington, VA 22201
phone: (703) 243-0344
email: alliance98@aol.com
website: www.alliancepolicy.org
website: www.alliancepolicy.org
China to receive $385m to eliminate HCFCs
CHINA: Up to $385m is to be given to China to end its production of R22 refrigerant.
The money from the Montreal Protocol's Multilateral Fund is designed to help ensure the entire elimination of China's industrial production of ozone depleting substances by the 2030.
China has agreed to retire its current HCFC production capacity and will also retire surplus production capacity that is currently not utilized.
According to the Chinese, the total amount of HCFCs to be eliminated will prevent the emission of over 4,300,000 tonnes of HCFCs, equal to 300,000 tonnes in terms of its ozone depletion potential, and 8 billion tonnes of carbon dioxide equivalent greenhouse gas emissions.
With China being the largest producer and consumer of HCFCs, this is potentially the largest project approved so far under the Multilateral Fund since its inception.
China will close and dismantle its production lines producing only HCFCs for uses controlled under the Montreal Protocol and ensure that any HCFC plants that will receive funding do not switch to producing HCFCs as industrial feedstock, a use not controlled by the Montreal Protocol. China will also coordinate with stakeholders and make best efforts to manage HCFC production and associated by-product production in HCFC plants in accordance with best practices to minimize associated climate impacts.
Over the next four years China will receive US $95m to cover the first stage of its HCFC production phase-out management plan (HPPMP) to assist the country to meet the freeze in HCFC production by 2013 and the reduction by 10% by 2015 as required by the Montreal Protocol's HCFC phase-out programme.
The latest data shows that China produces 92% of the total HCFC production of developing countries.
While the announcement was welcomed by the Environmental Investigation Agency (EIA), there are concerns to ensure that HFC23, a hugely damaging by-product of production, is also destroyed.
EIA is calling on China to formally pledge to destroy the HFC23 from all Chinese HCFC production facilities, including facilities which produce HCFC for feedstock.
"Elimination of China's production of HCFCs over the next 17 years is a great win for the environment," said Mark W Roberts, EIA's senior Policy advisor. "However, it will be a hollow victory unless China adopts measures to prevent HFC23 from being vented into the atmosphere."
The money from the Montreal Protocol's Multilateral Fund is designed to help ensure the entire elimination of China's industrial production of ozone depleting substances by the 2030.
China has agreed to retire its current HCFC production capacity and will also retire surplus production capacity that is currently not utilized.
According to the Chinese, the total amount of HCFCs to be eliminated will prevent the emission of over 4,300,000 tonnes of HCFCs, equal to 300,000 tonnes in terms of its ozone depletion potential, and 8 billion tonnes of carbon dioxide equivalent greenhouse gas emissions.
With China being the largest producer and consumer of HCFCs, this is potentially the largest project approved so far under the Multilateral Fund since its inception.
China will close and dismantle its production lines producing only HCFCs for uses controlled under the Montreal Protocol and ensure that any HCFC plants that will receive funding do not switch to producing HCFCs as industrial feedstock, a use not controlled by the Montreal Protocol. China will also coordinate with stakeholders and make best efforts to manage HCFC production and associated by-product production in HCFC plants in accordance with best practices to minimize associated climate impacts.
Over the next four years China will receive US $95m to cover the first stage of its HCFC production phase-out management plan (HPPMP) to assist the country to meet the freeze in HCFC production by 2013 and the reduction by 10% by 2015 as required by the Montreal Protocol's HCFC phase-out programme.
The latest data shows that China produces 92% of the total HCFC production of developing countries.
While the announcement was welcomed by the Environmental Investigation Agency (EIA), there are concerns to ensure that HFC23, a hugely damaging by-product of production, is also destroyed.
EIA is calling on China to formally pledge to destroy the HFC23 from all Chinese HCFC production facilities, including facilities which produce HCFC for feedstock.
"Elimination of China's production of HCFCs over the next 17 years is a great win for the environment," said Mark W Roberts, EIA's senior Policy advisor. "However, it will be a hollow victory unless China adopts measures to prevent HFC23 from being vented into the atmosphere."
Labels:
22,
a-gas remtec,
carbon dioxide,
china,
destruction,
eliminate hcfc,
HCFC,
HFC,
montreal protocol,
r-22,
r22,
recovery
Tuesday, April 16, 2013
Products Helpful in Recovery, Reclamation
By Peter Powell
April 8, 2013
While the reclamation process may not be meeting industry expectations, numerous manufacturers are offering equipment and devices that make the process easier than ever before. Listed below are a few of the industry’s newest products and technologies benefiting recovery and reclamation.
Atlantic Chemical & Equipment Co.’s (www.atlanticchemical.com) ACESeal AC/R and HVAC/R leak solutions seals small (up to 300 microns) leaks in condensers, evaporators, and refrigerant lines. The AC/R can handle up to 1.5 tons while the HVAC/R can handle up to 5 tons. The AceSeal is not a polymer-based sealant, so no drying agent is required. In addition, it does not require evacuation of refrigerant to input sealant, and the sealant blends with oil/refrigerant mix to travel to the leak. The oil and refrigerant escape through the lead while larger molecules in the sealant bond together to seal.
Fieldpiece Instruments’ (www.fieldpiece.com) SMAN4 is a four-port, wireless digital manifold that has a 3/8-inch port for evacuations and recovery. The four ports allow technicians to evacuate a system, pull a vacuum, add refrigerant, and dial in the charge at one time without having to hook or unhook any hoses.
Fluke Corp.’s (www.fluke.com) CNX Wire System wirelessly connects multiple measurement modules and sends simultaneous readings to a master device up to 20 meters away, allowing users to troubleshoot problems. The customizable tool set allows users to choose various measurement modules based on their specific troubleshooting scenario to read the measurements outside the arc flash zone.
General Tools & Instruments’ (www.generaltools.com) digital refrigerant leak detector (RLD400), which features a semiconductor sensor lifespan of more than 300 hours of operation or 10 years normal use. Three sensitivity levels let users choose the right level for specific environments.
Hilmor’s (www.hilmor.com) electronic gauge with vacuum sensor is a hybrid gauge with both analog and digital readouts with lights color coordinated to the selected refrigerant. It also features a micron gauge, self calibration, and is accurate to within 1 percent. The company also recently introduced a dual readout thermometer with thermocouple clamps that can be attached to any manifold using the hook provided. The tool features two digital temperature readouts so calculating superheat and subcool no longer requires multiple tools. An aluminum manifold has a forged aluminum body with rubberized handles, protective gauge boots, replaceable stainless steel valve stems, and a pressure indicator ring that allows users to mark a spot with a marker.
Polar Technology (www.refrigerantauthority.com) recently introduced TrakRef®, a proprietary and comprehensive refrigerant management program. As explained by the company, the product is designed to provide comprehensive and transparent tracking and management of refrigerants throughout their entire lifecycles. This includes from the time of purchase to deployment throughout maintenance cycles, through recovery and reclamation, to their final destruction at the end of the lifecycle. When the program is incorporated among the participating points in the supply chain, more of the original refrigerant is kept within the supply chain, ownership of the refrigerant can be accounted for, and regulatory compliance is inherently managed. It is available in three customized versions for contractors, distributors, and system owners.
Refco Mfg. Ltd.’s (www.refco.ch) Enviro is a one-knob operation refrigerant-recovery machine. It allows for recovery of all popular CFC, HCFC, and HFC refrigerants using an oil-less, air-cooled compressor. The Enviro is equipped with a self-purging mode as well as a built-in filter.
RefTec Intl. Systems LLC‘s (www.reftec.com) BullDog recovery/recycle/reclaim unit is available in three sizes, the unit processes R-22, R-134a, R-410A, R-11, R-123, and other common refrigerants with the same unit. It processes gas at speeds of 600 pounds per hour. Features include zero cross contamination of compressor oil to gas, portable design so it fits through standard 36-inch doorways, and single power source for unit and controls. The 80 percent tank-full float switch and 12-foot float cable ensure cylinders are not being overfilled.
Robinair (www.robinair.com) introduced the RG3000 Cube, a compact and lightweight refrigerant recovery machine from Promax. It is designed for liquid and vapor recovery of commonly used CFC, HFC, and HCFC refrigerants including R-410A. Equipped with a high-pressure shift-off switch, the machine automatically shuts off if pressure rises above 550 psi, helping to prevent pressure building in a tank or machine. The high-efficiency, cross-flow airflow design allows for more efficient refrigerant recovery leading to shorter cycle times, the company said. The company also displayed a refrigerant recovery, recycle, evacuate, and recharge machine. It can be used for multiple refrigerants. The portable machine’s microprocessor-controlled functions prompt the user through programming and signal preventive maintenance. The float chamber auto adjusts from liquid to vapor. The lockout panel prevents mixing of refrigerants. The heavy-duty filter drier removes moisture and acid from the refrigerant; it can handle 300 pounds between changeovers. The Promax® Cube™ refrigerant-recovery machine is capable of recovering both liquid and vapor refrigerant. The machine has a 1/3-hp, single-cylinder oil-less compressor.
Spectronics Corp.’s (www.spectroline.com) Optimax 400 leak-detection flashlight features power comparable to high-intensity, 150-W lamps, and an inspection range of up to 25 feet.
SuperCool’s (www.supercoolsliderule.com) Slide Rule is an R-22 and R-410A charging and duct calculator that performs superheat, subcooling, and duct calculations in one tool. Fixed meter-device charging is provided for R-22 and R-410A. TXV charging is also provided for R-22 and R-410A.
Superior Signal Co. LLC (www.superiorsignal.com) introduced the AccuTrak® VPE-GN ultrasonic leak detector with a 9 ½-inch gooseneck. The unit is sensitive to the ultrasonic sound of a turbulent gas leak. Using a technology called heterodyning, it translates the sound to a lower frequency which human ears can interpret, said the manufacturer. The device maintains the original sound characteristics, making it possible to distinguish leaks from other background sounds. The leak detector is designed to pinpoint leaks in air conditioning and refrigeration systems, acknowledging present air, vacuum, refrigerant, or gas leaks.
Testo AG’s (www.testo.com) testo 316-3 is a refrigerant-leak detector that includes a sensor head, transport case, calibration certificate, batteries, and a filter. It has one-button operation and the high/low sensitivity adjustment allows users to pinpoint the leak source. The company also offers the testo 310 and testo 320. The 310 is a residential combustion analyzer with a built-in condensate trap. The 320 is a high-definition combustion analyzer for both residential and commercial applications. There are many features with the 320, including its full-color, high-definition screen.
Universal Enterprises Inc. (www.ueitest.com) introduced the DRS220 digital refrigerant scale, which measures weight in both metric and English units, is programmable, and has a built-in alarm to indicate a programmed threshold has been exceeded.
Publication date: 4/8/2013
Atlantic Chemical & Equipment Co.’s (www.atlanticchemical.com) ACESeal AC/R and HVAC/R leak solutions seals small (up to 300 microns) leaks in condensers, evaporators, and refrigerant lines. The AC/R can handle up to 1.5 tons while the HVAC/R can handle up to 5 tons. The AceSeal is not a polymer-based sealant, so no drying agent is required. In addition, it does not require evacuation of refrigerant to input sealant, and the sealant blends with oil/refrigerant mix to travel to the leak. The oil and refrigerant escape through the lead while larger molecules in the sealant bond together to seal.
Fieldpiece Instruments’ (www.fieldpiece.com) SMAN4 is a four-port, wireless digital manifold that has a 3/8-inch port for evacuations and recovery. The four ports allow technicians to evacuate a system, pull a vacuum, add refrigerant, and dial in the charge at one time without having to hook or unhook any hoses.
Fluke Corp.’s (www.fluke.com) CNX Wire System wirelessly connects multiple measurement modules and sends simultaneous readings to a master device up to 20 meters away, allowing users to troubleshoot problems. The customizable tool set allows users to choose various measurement modules based on their specific troubleshooting scenario to read the measurements outside the arc flash zone.
General Tools & Instruments’ (www.generaltools.com) digital refrigerant leak detector (RLD400), which features a semiconductor sensor lifespan of more than 300 hours of operation or 10 years normal use. Three sensitivity levels let users choose the right level for specific environments.
Hilmor’s (www.hilmor.com) electronic gauge with vacuum sensor is a hybrid gauge with both analog and digital readouts with lights color coordinated to the selected refrigerant. It also features a micron gauge, self calibration, and is accurate to within 1 percent. The company also recently introduced a dual readout thermometer with thermocouple clamps that can be attached to any manifold using the hook provided. The tool features two digital temperature readouts so calculating superheat and subcool no longer requires multiple tools. An aluminum manifold has a forged aluminum body with rubberized handles, protective gauge boots, replaceable stainless steel valve stems, and a pressure indicator ring that allows users to mark a spot with a marker.
Polar Technology (www.refrigerantauthority.com) recently introduced TrakRef®, a proprietary and comprehensive refrigerant management program. As explained by the company, the product is designed to provide comprehensive and transparent tracking and management of refrigerants throughout their entire lifecycles. This includes from the time of purchase to deployment throughout maintenance cycles, through recovery and reclamation, to their final destruction at the end of the lifecycle. When the program is incorporated among the participating points in the supply chain, more of the original refrigerant is kept within the supply chain, ownership of the refrigerant can be accounted for, and regulatory compliance is inherently managed. It is available in three customized versions for contractors, distributors, and system owners.
Refco Mfg. Ltd.’s (www.refco.ch) Enviro is a one-knob operation refrigerant-recovery machine. It allows for recovery of all popular CFC, HCFC, and HFC refrigerants using an oil-less, air-cooled compressor. The Enviro is equipped with a self-purging mode as well as a built-in filter.
RefTec Intl. Systems LLC‘s (www.reftec.com) BullDog recovery/recycle/reclaim unit is available in three sizes, the unit processes R-22, R-134a, R-410A, R-11, R-123, and other common refrigerants with the same unit. It processes gas at speeds of 600 pounds per hour. Features include zero cross contamination of compressor oil to gas, portable design so it fits through standard 36-inch doorways, and single power source for unit and controls. The 80 percent tank-full float switch and 12-foot float cable ensure cylinders are not being overfilled.
Robinair (www.robinair.com) introduced the RG3000 Cube, a compact and lightweight refrigerant recovery machine from Promax. It is designed for liquid and vapor recovery of commonly used CFC, HFC, and HCFC refrigerants including R-410A. Equipped with a high-pressure shift-off switch, the machine automatically shuts off if pressure rises above 550 psi, helping to prevent pressure building in a tank or machine. The high-efficiency, cross-flow airflow design allows for more efficient refrigerant recovery leading to shorter cycle times, the company said. The company also displayed a refrigerant recovery, recycle, evacuate, and recharge machine. It can be used for multiple refrigerants. The portable machine’s microprocessor-controlled functions prompt the user through programming and signal preventive maintenance. The float chamber auto adjusts from liquid to vapor. The lockout panel prevents mixing of refrigerants. The heavy-duty filter drier removes moisture and acid from the refrigerant; it can handle 300 pounds between changeovers. The Promax® Cube™ refrigerant-recovery machine is capable of recovering both liquid and vapor refrigerant. The machine has a 1/3-hp, single-cylinder oil-less compressor.
Spectronics Corp.’s (www.spectroline.com) Optimax 400 leak-detection flashlight features power comparable to high-intensity, 150-W lamps, and an inspection range of up to 25 feet.
SuperCool’s (www.supercoolsliderule.com) Slide Rule is an R-22 and R-410A charging and duct calculator that performs superheat, subcooling, and duct calculations in one tool. Fixed meter-device charging is provided for R-22 and R-410A. TXV charging is also provided for R-22 and R-410A.
Superior Signal Co. LLC (www.superiorsignal.com) introduced the AccuTrak® VPE-GN ultrasonic leak detector with a 9 ½-inch gooseneck. The unit is sensitive to the ultrasonic sound of a turbulent gas leak. Using a technology called heterodyning, it translates the sound to a lower frequency which human ears can interpret, said the manufacturer. The device maintains the original sound characteristics, making it possible to distinguish leaks from other background sounds. The leak detector is designed to pinpoint leaks in air conditioning and refrigeration systems, acknowledging present air, vacuum, refrigerant, or gas leaks.
Testo AG’s (www.testo.com) testo 316-3 is a refrigerant-leak detector that includes a sensor head, transport case, calibration certificate, batteries, and a filter. It has one-button operation and the high/low sensitivity adjustment allows users to pinpoint the leak source. The company also offers the testo 310 and testo 320. The 310 is a residential combustion analyzer with a built-in condensate trap. The 320 is a high-definition combustion analyzer for both residential and commercial applications. There are many features with the 320, including its full-color, high-definition screen.
Universal Enterprises Inc. (www.ueitest.com) introduced the DRS220 digital refrigerant scale, which measures weight in both metric and English units, is programmable, and has a built-in alarm to indicate a programmed threshold has been exceeded.
Publication date: 4/8/2013
Peter Powell is Refrigeration Editor. E-mail him at peterpowell@achrnews.com.
Reclamation Looking for Jumpstart
By Peter Powell
April 8, 2013
![]() |
| A fractional distillation tower in Ohio. (Photo courtesy of A-Gas RemTec.) |
What’s the Problem?
“One of the major contributors to the flat or declining recovery rate is that many R-22 users have adopted a practice of reusing their recovered refrigerant,” said Gordon McKinney, vice president and COO, ICOR Intl. “Even though some might be making an attempt to recycle (filter out particulates and/or separate out oils), without properly analyzing the recovered gas to determine composition and quality, the user and equipment owner are rolling the dice.”Walt Baker, vice president of sales and marketing, Polar Technology, said, “A lot of this can be attributed to the commodity nature of refrigerant gases. Supplies are plentiful and prices reflect the availability of supplies. Therefore, the role of reclaim has been relegated to philosophies regarding environmental stewardship.”
Then there is the economics of reclamation for the contractor, said Ken Beringer, senior vice president of Airgas Refrigerants Inc. “The industry has not seen a significant increase in returned R-22 because, in my opinion, the majority of the product is harvested in small batches which do not have a great deal of value. Until January 2012, the returned gas had very little value and, in many cases, there was a disposal charge when the product was returned.”
Patti Conlan, who manages the reclaim program for Arkema, said, “In the past, the volume of reclaim has been low due to monetary gains not being passed down to the contractor level as an incentive to reclaim, as well as the possible legal and illegal reuse of R-22.”
Yet awareness is growing, said James Sweetman, president, Consolidated Refrigerant Solutions. “We have seen heightened awareness among contractors regarding the need to become involved in a viable reclaim program.”
Arkema’s Conlan is also predicting an uptick. “As the EPA has anticipated, we have just recently started to see an increase in reclaim coming back with the increasing price of R-22.” Said Beringer, “With the phaseout of HCFCs, the amount returned should increase as the price of used gas continues to rise. The very rapid appreciation in new product pricing may have led to the illegal practice of filtering used product and introducing it into the system of a different owner.” Ken Logan, president of A-Gas U.S. Holdings Inc., agrees, stating that “Currently the decreasing availability of virgin product is starting to make a difference. Over time the gap will widen further and the two will become inversely proportional.”
The HFC Factor
Also entering the equation is the industry’s focus on the use of HFC refrigerants as retrofits into systems originally designed for R-22. Owners of large amounts of equipment can move recovered R-22 around to not-yet-retrofitted systems and may or may not look at the reclamation option.Honeywell’s Foutz said, “Retrofit HFC refrigerants have been available for several years. To date, the availability of the retrofit HFC refrigerants has not stimulated significant growth in R-22 reclamation. As R-22 supplies tighten, the economic incentive should stimulate retrofits to HFC refrigerants and stimulate R-22 reclamation growth.”
ICOR’s McKinney looks at the HFC retrofit from a historical perspective. “If given the opportunity, equipment owners will squeeze the most life out of their systems as possible. It was R-12-alternative HCFC refrigerants that played the most significant role in closing the supply/demand gap during the CFC phase out. Based upon the tremendous market shift in the last few months to HFC alternatives, history is set to repeat itself.”
He noted, “In the near future the R-22 supply — virgin and reclaimed — will be set aside for critical applications where alternative refrigerants are not suitable, such as flooded chillers and systems that have highly sophisticated refrigerant-specific controls.”
For A-Gas’s Logan, this can be iffy. “Keep in mind, retrofitting a system to a refrigerant it wasn’t initially designed for normally involves compromises and not everything is capable of retrofit. The industry itself will decide what can and cannot be retrofitted successfully. Retrofit activity will help conserve supplies of reclaimed R-22 overall.”
Jump Start
What will jump start the sector?DuPont’s Goodge said, “It is a matter of supply-demand dynamics. If R-22 supply is limited, or the price increases dramatically, there is added incentive to manage the R-22 asset. A major element of a refrigerant management plan is extracting value from the installed R-22. Options include using recovered R-22 to do one or more of the following: gain access to lower-cost R-22 to continue to service equipment that remains on R-22, lowering the cost to retrofit existing equipment to an alternative HFC refrigerant, and/or reducing equipment replacement costs by extending the life of R-22 equipment by using either reclaimed R-22 or an HFC alternative.”
Airgas’s Beringer said it is a matter of economics, “People do not waste what is valuable. If the EPA had more enforcement, and made people accountable for their used product, then the culture would change. Higher pricing should help.”
As will awareness, said Consolidated’s Sweetman. “We believe that there is sufficient interest within the cooling and refrigeration industry to support increased reclamation. Companies that, for years, have been ‘kicking the can down the road’ or ‘dragging their butts’ are really starting to get on the ball. These contractors that have been conducting business as usual are finally reaching out to us for a more viable reclaim option.”
Publication date: 4/8/2013
Peter Powell is Refrigeration Editor. E-mail him at peterpowell@achrnews.com.
The Future of HFCs in Montreal Protocol
My Peter Powell
April 8, 2013
It’s easy to argue that no single development has impacted the HVACR industry as much as the Montreal Protocol. The international treaty, which was signed 25 years ago, ultimately phased out CFC and HCFC production; introduced refrigerant recovery, recycling, and reclamation; and, essentially, enveloped the HVACR industry under the power of the U.S. Environmental Protection Agency (EPA), which now dictates certifications and penalties related to the use and handling of refrigerants.
More than two decades later, the worldwide contract is still strongly impacting many sectors of the HVACR industry, including the decisions of contractors and service technicians. Ongoing discussions are currently underway, examining ways to incorporate HFCs into the protocol in order to phase down their use due to relatively high global warming potential (GWP). And while no changes are expected in the foreseeable future, these continuing conversations, and the potential developments pending, have surely caught the attention of those across the industry.
And, it appears to be working.
“The Montreal Protocol is widely recognized for being very effective in reducing ozone depleting substances including CFCs and HCFCs,” said Robert Wilkins, vice president of public affairs, Danfoss. “Although we do not expect atmospheric chlorine to return to pre-1980 levels until about 2050, it has peaked and has been trending downward for several years.”
The latest efforts to revise the Montreal Protocol include rating gases based on GWP, as well as ODP.
Rajan Rajendran, vice president of engineering services and sustainability for Emerson Climate Technologies, noted, “The U.S., Canada, and Mexico have proposed an amendment to the Montreal Protocol to address global warming with a phase down of HFCs. This effort has been in place for a few years now. While there are 107 other countries supporting it, there are other, more developing countries like India, China, and Brazil who oppose. One barrier that is often mentioned is that the Montreal Protocol has historically had a very clear mission of addressing ozone depletion, but climate change is outside of its charter.”
Danfoss’ Wilkins added, “The EPA and the Department of State jointly held a stakeholders meeting in Washington on Feb. 5 with American industry leaders and others to discuss possible steps forward. With industry representatives expressing support for a well-planned orderly global HFC phase down on a GWP-weighted basis, it is likely the North American proposal will be resubmitted in 2013 for consideration at this year’s annual meeting.”
But what happens after that is uncertain, although many expect minimal action for a few subsequent years.
Mack McFarland, environmental fellow, DuPont Chemicals & Fluoroproducts, said, “The proposed amendment to the Montreal Protocol has not yet been endorsed by all of the developing countries. Amendments are adopted by consensus. Discussions continue with more and more countries voicing their support each year. I think the industry views the predictable process under the Montreal Protocol as preferable to country-by-country command and control regimes.”
Rajendran agreed. “While there are efforts to make some changes in the protocol, I don’t believe we’ll see any changes in the next few years.”
According to the website R-744.com, “The debate did advance, with countries discussing HFC amendment proposals in an informal setting, as well as requesting more information on the availability of environmentally sound alternatives to ozone depleting substances.”
R-744.com noted that this debate has spanned four years, without resolution. In his second inaugural address President Barack Obama said, “We will respond to the threat of climate change, knowing that the failure to do so would betray our children and future generations.” He did not specify any specific proposals during this speech.
A Feb. 12 report from the White House, titled, “The President’s Plan for a Strong Middle Class and a Strong America,” revived calls for more reliance on solar and wind energy generation. The only reference to climate change was the statement, “The president has directed his cabinet to identify executive actions from across the administration to help reduce pollution, prepare our cities and nation for the worsening effects of climate change, and accelerate the transition to more sustainable sources of energy.”
But most do not see this as an omen for unilateral action. For one, a divided Congress seems unlikely to act on potentially costly initiatives. And many in the industry see the EPA wanting to work in the framework of a global consensus.
At the same time, Rajendran did suggest, “The HVACR industry in the U.S. should be watching the emerging U.S. state government regulations out of the West and Northeast as well as potential U.S. government actions and regulations on greenhouse gasses.”
DuPont’s McFarland said, “There are a broad range of global activities under way to address greenhouse gas emissions, such as the U.S. CAFE standard for lightweight motor vehicles, renewable fuels, electricity programs in various countries, and cap-and-trade pilots in China. We anticipate that absent of a global agreement such as the Montreal Protocol, the U.S. government will seek ways to reduce HFC emissions under its current authority.”
But, in the context of a global perspective, Wilkins said progress may occur slowly. “Any changes to the Montreal Protocol would take a few years to enact. If India and China could be persuaded to support an HFC phase down, leading to a global consensus, the Montreal Protocol would then undergo negotiations to finalize the amendment and provide specific targets and timetables for phasing down HFCs globally. The amendment would then need to be ratified country by country. In the U.S., that would likely require action by the Senate. Once approved, each country could begin its own process for phasing down HFCs — similar to the phase down of CFCs and HCFCs.”
Even then, many ratifiers had problems reducing GHG emissions to promised levels. However, more than 100 nations have pledged support behind the regulation of GHG emissions through the Montreal Protocol, and a growing number of countries are ready to join on, if a draft is ever presented.
Mack McFarland, environmental fellow, DuPont Chemicals & Fluoroproducts, said, “While there are no discussions under the Kyoto Protocol specific to the HVACR industry, there are active discussions under the Montreal Protocol.”
Robert Wilkins, vice president of public affairs, Danfoss, acknowledged that climate change is emerging as an important issue for the Obama administration. “Since the U.S. never ratified the Kyoto Protocol, and nothing has developed regarding refrigerants, there isn’t likely to be any impact on the HVACR industry.”
Rajan Rajendran, vice president of engineering services and sustainability for Emerson Climate Technologies, said climate-change regulations could still surface in the U.S.
“From the Kyoto Protocol point of view, which is focused on climate change, the HVACR industry in the U.S. should be watching the emerging U.S. state government regulations on greenhouse gases.”
Publication date: 4/8/2013
More than two decades later, the worldwide contract is still strongly impacting many sectors of the HVACR industry, including the decisions of contractors and service technicians. Ongoing discussions are currently underway, examining ways to incorporate HFCs into the protocol in order to phase down their use due to relatively high global warming potential (GWP). And while no changes are expected in the foreseeable future, these continuing conversations, and the potential developments pending, have surely caught the attention of those across the industry.
Good News
But first, the good news: The protocol was designed to protect the ozone layer by phasing out the production of substances found to be responsible for ozone depletion, those having ozone depleting potential (ODP).And, it appears to be working.
“The Montreal Protocol is widely recognized for being very effective in reducing ozone depleting substances including CFCs and HCFCs,” said Robert Wilkins, vice president of public affairs, Danfoss. “Although we do not expect atmospheric chlorine to return to pre-1980 levels until about 2050, it has peaked and has been trending downward for several years.”
The Emergence of HFCs
With the HVACR industry forced to turn away from CFCs and HCFCs, it has moved on to HFCs, which include no ODP. However, many HFCs carried a high GWP due to their abilities to trap infrared radiations in the atmosphere, which does contribute to the greenhouse effect.The latest efforts to revise the Montreal Protocol include rating gases based on GWP, as well as ODP.
Rajan Rajendran, vice president of engineering services and sustainability for Emerson Climate Technologies, noted, “The U.S., Canada, and Mexico have proposed an amendment to the Montreal Protocol to address global warming with a phase down of HFCs. This effort has been in place for a few years now. While there are 107 other countries supporting it, there are other, more developing countries like India, China, and Brazil who oppose. One barrier that is often mentioned is that the Montreal Protocol has historically had a very clear mission of addressing ozone depletion, but climate change is outside of its charter.”
Danfoss’ Wilkins added, “The EPA and the Department of State jointly held a stakeholders meeting in Washington on Feb. 5 with American industry leaders and others to discuss possible steps forward. With industry representatives expressing support for a well-planned orderly global HFC phase down on a GWP-weighted basis, it is likely the North American proposal will be resubmitted in 2013 for consideration at this year’s annual meeting.”
But what happens after that is uncertain, although many expect minimal action for a few subsequent years.
Mack McFarland, environmental fellow, DuPont Chemicals & Fluoroproducts, said, “The proposed amendment to the Montreal Protocol has not yet been endorsed by all of the developing countries. Amendments are adopted by consensus. Discussions continue with more and more countries voicing their support each year. I think the industry views the predictable process under the Montreal Protocol as preferable to country-by-country command and control regimes.”
Rajendran agreed. “While there are efforts to make some changes in the protocol, I don’t believe we’ll see any changes in the next few years.”
Europe and the US
European leaders are conversationally discussing HFC regulations based on GWP.According to the website R-744.com, “The debate did advance, with countries discussing HFC amendment proposals in an informal setting, as well as requesting more information on the availability of environmentally sound alternatives to ozone depleting substances.”
R-744.com noted that this debate has spanned four years, without resolution. In his second inaugural address President Barack Obama said, “We will respond to the threat of climate change, knowing that the failure to do so would betray our children and future generations.” He did not specify any specific proposals during this speech.
A Feb. 12 report from the White House, titled, “The President’s Plan for a Strong Middle Class and a Strong America,” revived calls for more reliance on solar and wind energy generation. The only reference to climate change was the statement, “The president has directed his cabinet to identify executive actions from across the administration to help reduce pollution, prepare our cities and nation for the worsening effects of climate change, and accelerate the transition to more sustainable sources of energy.”
But most do not see this as an omen for unilateral action. For one, a divided Congress seems unlikely to act on potentially costly initiatives. And many in the industry see the EPA wanting to work in the framework of a global consensus.
At the same time, Rajendran did suggest, “The HVACR industry in the U.S. should be watching the emerging U.S. state government regulations out of the West and Northeast as well as potential U.S. government actions and regulations on greenhouse gasses.”
DuPont’s McFarland said, “There are a broad range of global activities under way to address greenhouse gas emissions, such as the U.S. CAFE standard for lightweight motor vehicles, renewable fuels, electricity programs in various countries, and cap-and-trade pilots in China. We anticipate that absent of a global agreement such as the Montreal Protocol, the U.S. government will seek ways to reduce HFC emissions under its current authority.”
But, in the context of a global perspective, Wilkins said progress may occur slowly. “Any changes to the Montreal Protocol would take a few years to enact. If India and China could be persuaded to support an HFC phase down, leading to a global consensus, the Montreal Protocol would then undergo negotiations to finalize the amendment and provide specific targets and timetables for phasing down HFCs globally. The amendment would then need to be ratified country by country. In the U.S., that would likely require action by the Senate. Once approved, each country could begin its own process for phasing down HFCs — similar to the phase down of CFCs and HCFCs.”
SIDEBAR: A No-Go for Kyoto
If changes to the Montreal Protocol are slow starters in regards to any additional impact on HVACR contractors, the Kyoto Protocol is a non-starter. Kyoto was to be the document to obligate countries, starting in 2005, to reduce greenhouse gas emissions (GHG). Many countries signed and ratified it. The U.S. signed it, but failed to ratify it and Canada withdrew from it in 2011.Even then, many ratifiers had problems reducing GHG emissions to promised levels. However, more than 100 nations have pledged support behind the regulation of GHG emissions through the Montreal Protocol, and a growing number of countries are ready to join on, if a draft is ever presented.
Mack McFarland, environmental fellow, DuPont Chemicals & Fluoroproducts, said, “While there are no discussions under the Kyoto Protocol specific to the HVACR industry, there are active discussions under the Montreal Protocol.”
Robert Wilkins, vice president of public affairs, Danfoss, acknowledged that climate change is emerging as an important issue for the Obama administration. “Since the U.S. never ratified the Kyoto Protocol, and nothing has developed regarding refrigerants, there isn’t likely to be any impact on the HVACR industry.”
Rajan Rajendran, vice president of engineering services and sustainability for Emerson Climate Technologies, said climate-change regulations could still surface in the U.S.
“From the Kyoto Protocol point of view, which is focused on climate change, the HVACR industry in the U.S. should be watching the emerging U.S. state government regulations on greenhouse gases.”
Publication date: 4/8/2013
Peter Powell is Refrigeration Editor. E-mail him at peterpowell@achrnews.com.
Monday, April 8, 2013
EPA Finalizes R-22 Allocations for 2012-2014
By Charlie McCrudden | April 4, 2013 | Leave a Comment
On April 3, the U.S. EPA published in the Federal Register the final rule adjusting the allocation of HCFCs (including R-22 refrigerants) for the years 2012-2014 (2013 Final Adjustment Rule).
According to the Final Adjustment Rule, R-22 allowances for 2013 will rise by about 13% relative to 2012, and decrease by 20% in 2014 relative to 2012. The allocations for the years 2015-2019 will be set in a subsequent rulemaking. These allocations became effective on April 3, 2013.
See the chart below (click to enlarge).

Contractors may want to contact their wholesalers or gas distributors to inquire about any changes in pricing or sales policies in light of the 2013 Final Adjustment Rule. Despite the unexpected increase in the allocations for 2013, the market remains volatile and prices for R-22 may not respond to the increased supply.
Background
The U.S. EPA controls the production and use of HCFCs, including the refrigerant R-22, through a cap and trade program. The amount of virgin R-22 that can be produced in a given year is set by annual allocations. The production and use of HCFCs is slowly being phased out in the United States, because these chemicals are known to damage the ozone layer when released into the atmosphere.
In 2011 the EPA was ordered to reopen the 2009 Allocation Rule that set the allocations for the years 2010-2014. The order came from the U.S. Court of Appeals for the District of Columbia Circuit in a lawsuit filed by two gas producers who charged that the EPA had failed to recognize their legally traded allocations.
In August 2011, the EPA proposed to adjust the R-22 allocations in the three remaining years of the 2009 Allocation Rule (2012-2014).
Based on consultation with industry stakeholders, the EPA determined there was an oversupply of virgin R-22 in the marketplace, evident with low demand, increased reuse of R-22, and low wholesale prices. In 2010, R-22 producers only utilized 86% of their allocations. A trade organization representing the manufacturers and importers of R-22 supported these claims, and advocated for a 20% reduction in allocations for 2012-2014.
Since 2012 refrigerant producers and importers have been operating with only temporary, 12 month authority through “No Action Assurance” letters from the EPA. Without a finalized Adjustment Rule, and without the No Action Assurance letters, virgin R-22 could not be legally produced or imported into the United States. The No Action Assurance letter from the EPA advised allocations would be less than the 2009 Allocation Rule.
The 2013 Final Adjustment Rule sets the allocations for the years 2012 (retroactively), 2013, and 2014.
In 2013, the total amount of R-22 allocated to all producers and importers is about 62.8 million pounds, compared with about 55.4 million pounds allocated for 2012. In 2014, the total allocation of R-22 will drop to 51 million pounds.
According to the Final Adjustment Rule, R-22 allowances for 2013 will rise by about 13% relative to 2012, and decrease by 20% in 2014 relative to 2012. The allocations for the years 2015-2019 will be set in a subsequent rulemaking. These allocations became effective on April 3, 2013.
See the chart below (click to enlarge).

Background
The U.S. EPA controls the production and use of HCFCs, including the refrigerant R-22, through a cap and trade program. The amount of virgin R-22 that can be produced in a given year is set by annual allocations. The production and use of HCFCs is slowly being phased out in the United States, because these chemicals are known to damage the ozone layer when released into the atmosphere.
In 2011 the EPA was ordered to reopen the 2009 Allocation Rule that set the allocations for the years 2010-2014. The order came from the U.S. Court of Appeals for the District of Columbia Circuit in a lawsuit filed by two gas producers who charged that the EPA had failed to recognize their legally traded allocations.
In August 2011, the EPA proposed to adjust the R-22 allocations in the three remaining years of the 2009 Allocation Rule (2012-2014).
Based on consultation with industry stakeholders, the EPA determined there was an oversupply of virgin R-22 in the marketplace, evident with low demand, increased reuse of R-22, and low wholesale prices. In 2010, R-22 producers only utilized 86% of their allocations. A trade organization representing the manufacturers and importers of R-22 supported these claims, and advocated for a 20% reduction in allocations for 2012-2014.
Since 2012 refrigerant producers and importers have been operating with only temporary, 12 month authority through “No Action Assurance” letters from the EPA. Without a finalized Adjustment Rule, and without the No Action Assurance letters, virgin R-22 could not be legally produced or imported into the United States. The No Action Assurance letter from the EPA advised allocations would be less than the 2009 Allocation Rule.
The 2013 Final Adjustment Rule sets the allocations for the years 2012 (retroactively), 2013, and 2014.
In 2013, the total amount of R-22 allocated to all producers and importers is about 62.8 million pounds, compared with about 55.4 million pounds allocated for 2012. In 2014, the total allocation of R-22 will drop to 51 million pounds.
How to Choose the Right R-22 Retrofit Refrigerant
This webinar will provide a technical overview of the many different R-22 retrofits available today and how to choose the right retrofit solution. Also a brief discussion of R-22 market dynamics will be covered. A summary of what products are offered and for which specific application each one is best suited will be included along with selection criteria. The tradeoffs and compromises that occur when using retrofit refrigerants in a system specifically designed for R-22 will also be addressed. After attending this seminar, you will:
|
Wednesday, March 20, 2013
The EPA Cracks Down on Illegal R-22 Importation and Sale
The Alliance for Responsible Atmospheric Policy, an industry coalition, said in
November 2012 the United States government successfully concluded 11 criminal
and civil cases related to HCFC-22 refrigerant smuggling over the last two
years. The alliance said that individuals and companies were found guilty of
various crimes related to the illegal importation or sale of over 3.3 million
pounds of R-22, fined over $1.5 million, required to forfeit proceeds of almost
$2.7 million, and received jail and probation amounting to over 26 years.
“The U.S. government is very serious about tracking down those who illegally import or sell HCFC-22. Anyone devising illegal schemes to import or sell this refrigerant is on notice that the U.S. will arrest and convict you,” said Dave Stirpe, alliance executive director.
Stirpe went on to say that the alliance cautions industry and the public to be certain that their R-22 refrigerant purchases are legal, and to report any offers to buy illegally imported refrigerants to the U.S. Environmental Protection Agency (EPA). R-22 refrigerant may be legally produced domestically and imported into the U.S. provided that EPA-issued quota allowances are expended. Anyone importing HCFCs without legal allowances is in violation of federal law. R-22 is generally used to service and maintain existing commercial air conditioning and refrigeration equipment. Newly produced equipment generally relies on HFCs and other refrigerants.
"Purchasers of the illegal refrigerant are at risk,” Stirpe said. “The government may confiscate any illegally imported refrigerant, even if it has been passed down through the marketplace, and it may prosecute purchasers who knowingly buy illegal material. Consumers should also be wary of the refrigerant since some of the imported material has been found to be of poor quality, or it could be counterfeit.”
Some other points made by the alliance about importation and purchase of R-22:
• The recipient of a trade can show a letter from EPA acknowledging the approval of the trade.
• Purchasers who question the legitimacy of an HCFC-22 importer should request a copy of the EPA approval letter from the seller.
“The U.S. government is very serious about tracking down those who illegally import or sell HCFC-22. Anyone devising illegal schemes to import or sell this refrigerant is on notice that the U.S. will arrest and convict you,” said Dave Stirpe, alliance executive director.
Only Buy Legal R-22
Stirpe went on to say that the alliance cautions industry and the public to be certain that their R-22 refrigerant purchases are legal, and to report any offers to buy illegally imported refrigerants to the U.S. Environmental Protection Agency (EPA). R-22 refrigerant may be legally produced domestically and imported into the U.S. provided that EPA-issued quota allowances are expended. Anyone importing HCFCs without legal allowances is in violation of federal law. R-22 is generally used to service and maintain existing commercial air conditioning and refrigeration equipment. Newly produced equipment generally relies on HFCs and other refrigerants.
"Purchasers of the illegal refrigerant are at risk,” Stirpe said. “The government may confiscate any illegally imported refrigerant, even if it has been passed down through the marketplace, and it may prosecute purchasers who knowingly buy illegal material. Consumers should also be wary of the refrigerant since some of the imported material has been found to be of poor quality, or it could be counterfeit.”
He went on to say that purchasers of imported R-22
should verify that their importer is an authorized EPA baseline consumption
allowance holder, or was involved in a subsequent legal trade of consumption
allowances. An EPA list of baseline consumption allowance holders can be found
at www.epa.gov/ozone/title6/allowance.html.
Some other points made by the alliance about importation and purchase of R-22:
• The recipient of a trade can show a letter from EPA acknowledging the approval of the trade.
• Purchasers who question the legitimacy of an HCFC-22 importer should request a copy of the EPA approval letter from the seller.
• Importers of used HCFCs must follow EPA petition
process requirements listed at www.epa.gov/ozone/title6/imports/usedclasstwo.html.
• Violations should be reported at www.epa.gov/tips/, and may be
done so anonymously.
Monday, March 18, 2013
Beyond Familiar HFCs
DALLAS — While much of the buzz at the AHR Expo was on dwindling supplies of
new HCFC-22, reclamation of that refrigerant, and use of alternative HFCs in
retrofits, a number of conversations centered on alternatives beyond familiar
HFCs. Even with the regulatory landscape unclear, the high global warming
potential (GWP) of some HFCs was causing a stir on the show floor.
While HFC-410A was firmly encamped as the refrigerant of choice for air conditioning in a large number of applications, its high GWP was turning attention in Dallas to use of HFC-32 as a stand-alone refrigerant. HFC-410A, which was introduced to the industry more than a decade ago as an alternative to R-22 in new equipment, carries a high GWP. R-32 has a much lower GWP (675 vs. 2088). This is a topic that has been in the industry for a number of years, since it first surfaced as a high-profile topic in 2010 at industry conferences hosted by Purdue University.
Danfoss furthered this notion at its AHR Expo booth, where it displayed its SG scroll compressor with the signage: “Get ready for Green Solutions with R-32.”
HFO refrigerants are widely recognized as the next generation of refrigerants. The alternative garnered its fair share of attention at the expo as well.
On the show floor, Honeywell was issuing a statement about its HFO refrigerant 1234ze which it markets as Solstice L-41. The manufacturer compared its refrigerant, stating that their refrigerant offers “significant advantages over another (R-410A) alternative, R-32, which has a higher GWP and limitations related to high-discharge temperatures, which can affect performance and durability in hot climates, and may also require new lubricants.”
Honeywell boasted that Solstice L-41 offers a 75 percent reduction in GWP compared to R-410A and is intended to replace R-410A in residential and light commercial air conditioning and heat pump applications. In addition to its lower GWP, Solstice L-41 offers excellent energy efficiency, is cost effective, and can be used in existing equipment designs with minimal changes.
“Honeywell has been working closely with leading equipment manufacturers to optimize Solstice L-41 to meet the demanding requirements of both stationary air conditioning and heat pump applications across a broad range of operating conditions,” said Tom Morris, director of commercial development for Honeywell Fluorine Products. “Solstice L-41 will allow these manufacturers to offer more environmentally friendly air conditioning and heat pump systems to help address climate change.”
Solstice L-41 is based on Honeywell’s HFO-1234ze technology, which was “first introduced in 2008 and has since been proven and commercialized for chillers, insulating-foam, and aerosol applications. A new HFO-1234ze manufacturing plant is currently under construction to meet the needs of equipment manufacturers.”
Even with its involvement with R-32 in some applications, Danfoss was waving the HFO flag. The company used a press conference to announce its involvement with HFO-1234ze in its Turbocor line and the commercialization of TG310 compressors, which were released as a developmental prototype in early 2012. The company said the compressors “utilize the ultra-low GWP, zero ozone depletion potential (ODP) refrigerant HFO-1234ze.”
As the HFO sector evolves it is becoming clear that there are HFOs with A1 (nonflammable) safety ratings and those that have A2L (slightly flammable) safety ratings. A1s generally carry higher GWPs than A2Ls. This means the sector will have to sort itself out. If regulations set especially low GWP maximums, only A2Ls would be allowed to establish a beachhead; which would require UL certification, as well as building code modifications, for the installation of such equipment in certain portions of the country.
One HFO topic that appears to be sorting itself out is in the automotive sector. After automaker Daimler expressed some safety concerns over the use of HFO-1234yf in vehicle air conditioners last fall, General Motors issued a statement at the time of the expo pledging to move ahead with the use of that HFO in its vehicles — saying that in all its testing, the refrigerant proved safe and effective.
A number of manufacturers showed equipment for natural refrigerants such as HCs and especially CO2 at the expo.
During a Danfoss press briefing, Scott Martin, director of sustainable technologies, Hill Phoenix, spoke about CO2 developments that his company has been doing in conjunction with Danfoss. He said that his company’s systems that utilize CO2 technology offer several distinct advantages over traditional DX-refrigeration systems. “These CO2 sub-critical systems deliver superior refrigeration performance with enhanced sustainability, reduced refrigerant-charge requirements, and greatly reduced refrigerant-leak rates. Simply, they are the most energy-efficient and environmentally friendly refrigeration systems available in the industry today.”
He also noted advances in CO2 in transcritical-application use of which are growing in North America. That was reinforced on the show floor at the Bitzer booth where a transcritical-CO2 compressor was displayed.
The editors of the European-based online publication R744.com also walked the floor at AHR and provided a viewpoint for its global readership regarding the future direction of CO2 use in the United States.
“The pure number of booths displaying CO2 refrigerant components and systems has not significantly increased from last year’s trade show. However, the showcase of breakthrough innovations, prototypes, and optimized product lines in R-744 (CO2) compressors, heat pumps, or air conditioners, as well as commercialization announcements expected for the next 12 months are all solid indicators that the U.S. market is getting serious about R-744.”
Low-GWP HFCs
While HFC-410A was firmly encamped as the refrigerant of choice for air conditioning in a large number of applications, its high GWP was turning attention in Dallas to use of HFC-32 as a stand-alone refrigerant. HFC-410A, which was introduced to the industry more than a decade ago as an alternative to R-22 in new equipment, carries a high GWP. R-32 has a much lower GWP (675 vs. 2088). This is a topic that has been in the industry for a number of years, since it first surfaced as a high-profile topic in 2010 at industry conferences hosted by Purdue University.
Danfoss furthered this notion at its AHR Expo booth, where it displayed its SG scroll compressor with the signage: “Get ready for Green Solutions with R-32.”
HFOs on Display
HFO refrigerants are widely recognized as the next generation of refrigerants. The alternative garnered its fair share of attention at the expo as well.
On the show floor, Honeywell was issuing a statement about its HFO refrigerant 1234ze which it markets as Solstice L-41. The manufacturer compared its refrigerant, stating that their refrigerant offers “significant advantages over another (R-410A) alternative, R-32, which has a higher GWP and limitations related to high-discharge temperatures, which can affect performance and durability in hot climates, and may also require new lubricants.”
Honeywell boasted that Solstice L-41 offers a 75 percent reduction in GWP compared to R-410A and is intended to replace R-410A in residential and light commercial air conditioning and heat pump applications. In addition to its lower GWP, Solstice L-41 offers excellent energy efficiency, is cost effective, and can be used in existing equipment designs with minimal changes.
“Honeywell has been working closely with leading equipment manufacturers to optimize Solstice L-41 to meet the demanding requirements of both stationary air conditioning and heat pump applications across a broad range of operating conditions,” said Tom Morris, director of commercial development for Honeywell Fluorine Products. “Solstice L-41 will allow these manufacturers to offer more environmentally friendly air conditioning and heat pump systems to help address climate change.”
Solstice L-41 is based on Honeywell’s HFO-1234ze technology, which was “first introduced in 2008 and has since been proven and commercialized for chillers, insulating-foam, and aerosol applications. A new HFO-1234ze manufacturing plant is currently under construction to meet the needs of equipment manufacturers.”
Even with its involvement with R-32 in some applications, Danfoss was waving the HFO flag. The company used a press conference to announce its involvement with HFO-1234ze in its Turbocor line and the commercialization of TG310 compressors, which were released as a developmental prototype in early 2012. The company said the compressors “utilize the ultra-low GWP, zero ozone depletion potential (ODP) refrigerant HFO-1234ze.”
Safety First
As the HFO sector evolves it is becoming clear that there are HFOs with A1 (nonflammable) safety ratings and those that have A2L (slightly flammable) safety ratings. A1s generally carry higher GWPs than A2Ls. This means the sector will have to sort itself out. If regulations set especially low GWP maximums, only A2Ls would be allowed to establish a beachhead; which would require UL certification, as well as building code modifications, for the installation of such equipment in certain portions of the country.
One HFO topic that appears to be sorting itself out is in the automotive sector. After automaker Daimler expressed some safety concerns over the use of HFO-1234yf in vehicle air conditioners last fall, General Motors issued a statement at the time of the expo pledging to move ahead with the use of that HFO in its vehicles — saying that in all its testing, the refrigerant proved safe and effective.
HCs and CO2
A number of manufacturers showed equipment for natural refrigerants such as HCs and especially CO2 at the expo.
During a Danfoss press briefing, Scott Martin, director of sustainable technologies, Hill Phoenix, spoke about CO2 developments that his company has been doing in conjunction with Danfoss. He said that his company’s systems that utilize CO2 technology offer several distinct advantages over traditional DX-refrigeration systems. “These CO2 sub-critical systems deliver superior refrigeration performance with enhanced sustainability, reduced refrigerant-charge requirements, and greatly reduced refrigerant-leak rates. Simply, they are the most energy-efficient and environmentally friendly refrigeration systems available in the industry today.”
He also noted advances in CO2 in transcritical-application use of which are growing in North America. That was reinforced on the show floor at the Bitzer booth where a transcritical-CO2 compressor was displayed.
The editors of the European-based online publication R744.com also walked the floor at AHR and provided a viewpoint for its global readership regarding the future direction of CO2 use in the United States.
“The pure number of booths displaying CO2 refrigerant components and systems has not significantly increased from last year’s trade show. However, the showcase of breakthrough innovations, prototypes, and optimized product lines in R-744 (CO2) compressors, heat pumps, or air conditioners, as well as commercialization announcements expected for the next 12 months are all solid indicators that the U.S. market is getting serious about R-744.”