Monday, March 11, 2013
Converting Away From R-22
Editor’s Note: The following article was prepared by ICOR International and
references some technologies and products specific to the company.
With the impending phaseout of R-22 looming, the price and availability of the product will soon make it impractical to use.
With virtually tens of millions of R-22-designed a/c systems in operation, refrigerant users and equipment owners will need to employ a number of alternative options to satisfy their cooling needs. Due to the special application designs and cooling requirements found in multifamily structures, there are a unique set of challenges in maintaining cooling equipment and fewer practical options.
It is illegal to purposely vent any refrigerant. All refrigerant users must possess an EPA 608 certification (required by law under The Clean Air Act) to recover all refrigerants. Recovered refrigerants are to be recycled or returned to an EPA-registered reclaim service provider (one example of which is Refri-Claim [www.refri-claim.com]).
The law does allow equipment owners to recycle and reuse refrigerants in their own equipment without processing it through a reclaim company. However, this practice adds additional costs in the form of equipment, labor, and energy, and, if done improperly, can create additional service problems and even equipment failures.
HFC-410A is the non-ozone depleting replacement of choice by new equipment manufactures. Since R-410A operational pressures are much higher than that of R-22, R-410A-designed systems incorporate unique materials and components. For this reason users cannot use R-22 in an R-410A-designed system, or use R-410A in an R-22-designed system. The refrigerants must be segregated and used only in systems designed for their unique characteristics.
Even though R-410A is a highly efficient refrigerant and the equipment’s physical footprint does not pose any new challenges, the cost of replacing an existing R-22 designed system with an R-410A system may be impractical. With most multifamily systems, the evaporator (indoor unit) has a much longer lifespan than does the condenser (outdoor unit). However, R-410A pressures require the replacement of the outdoor unit as well as the indoor unit. And since R-410A systems require the use of a product specific lubricant — POE oil — the system piping (line sets) must be flushed with a special solvent to remove any build up along the piping walls.
For equipment owners with a restrictive budget, full equipment replacement to R-410A may be impractical.
The simplest and least costly option to maintaining an existing piece of R-22 equipment is to convert the system to a direct replacement refrigerant. For example, HFC-422B (marketed by ICOR International as NU-22B) is a non-ozone depleting, nontoxic, and nonflammable direct replacement that nearly duplicates the operating characteristics of R-22. System conversions to R-422B do not require the use of any product-specific materials or components. Therefore decision-makers can extend the lifespan of both the indoor and outdoor units and avoid any costs associated with flushing or replacing system piping.
Here is the conversion process using R-422B as an example:
1. Recover all of the R-22 from the system following EPA regulations.
2. Complete all necessary system services and repairs.
3. Pressurize system and performance leak check.
4. Pull system into a vacuum.
5. With the system off, initially charge R-422B in the system to 80 percent of the original R-22 charge as a liquid. Note: Charging a system with R-422B as a vapor will reduce system performance.
6. Start system and allow pressure to stabilize.
7. To maximize system performance on a fixed orifice system, check compressor superheat; on expansion valve units check system subcooling. Adjust charge as necessary. Note: Refer to the original equipment manufacturer’s superheat and subcooling specifications.
8. Leak check the system and establish preventive maintenance schedule.
A special note: For large-tonnage equipment or unique systems, and or applications, contact ICOR’s Tech-2-Tech department for conversion assistance. Do not use R-422B or any other 400 Series refrigerant in a flooded evaporator application.
With the impending phaseout of R-22 looming, the price and availability of the product will soon make it impractical to use.
With virtually tens of millions of R-22-designed a/c systems in operation, refrigerant users and equipment owners will need to employ a number of alternative options to satisfy their cooling needs. Due to the special application designs and cooling requirements found in multifamily structures, there are a unique set of challenges in maintaining cooling equipment and fewer practical options.
It is illegal to purposely vent any refrigerant. All refrigerant users must possess an EPA 608 certification (required by law under The Clean Air Act) to recover all refrigerants. Recovered refrigerants are to be recycled or returned to an EPA-registered reclaim service provider (one example of which is Refri-Claim [www.refri-claim.com]).
The law does allow equipment owners to recycle and reuse refrigerants in their own equipment without processing it through a reclaim company. However, this practice adds additional costs in the form of equipment, labor, and energy, and, if done improperly, can create additional service problems and even equipment failures.
Equipment Replacement
HFC-410A is the non-ozone depleting replacement of choice by new equipment manufactures. Since R-410A operational pressures are much higher than that of R-22, R-410A-designed systems incorporate unique materials and components. For this reason users cannot use R-22 in an R-410A-designed system, or use R-410A in an R-22-designed system. The refrigerants must be segregated and used only in systems designed for their unique characteristics.
Even though R-410A is a highly efficient refrigerant and the equipment’s physical footprint does not pose any new challenges, the cost of replacing an existing R-22 designed system with an R-410A system may be impractical. With most multifamily systems, the evaporator (indoor unit) has a much longer lifespan than does the condenser (outdoor unit). However, R-410A pressures require the replacement of the outdoor unit as well as the indoor unit. And since R-410A systems require the use of a product specific lubricant — POE oil — the system piping (line sets) must be flushed with a special solvent to remove any build up along the piping walls.
Refrigerant Conversion
For equipment owners with a restrictive budget, full equipment replacement to R-410A may be impractical.
The simplest and least costly option to maintaining an existing piece of R-22 equipment is to convert the system to a direct replacement refrigerant. For example, HFC-422B (marketed by ICOR International as NU-22B) is a non-ozone depleting, nontoxic, and nonflammable direct replacement that nearly duplicates the operating characteristics of R-22. System conversions to R-422B do not require the use of any product-specific materials or components. Therefore decision-makers can extend the lifespan of both the indoor and outdoor units and avoid any costs associated with flushing or replacing system piping.
The Conversion Process
Here is the conversion process using R-422B as an example:
1. Recover all of the R-22 from the system following EPA regulations.
2. Complete all necessary system services and repairs.
3. Pressurize system and performance leak check.
4. Pull system into a vacuum.
5. With the system off, initially charge R-422B in the system to 80 percent of the original R-22 charge as a liquid. Note: Charging a system with R-422B as a vapor will reduce system performance.
6. Start system and allow pressure to stabilize.
7. To maximize system performance on a fixed orifice system, check compressor superheat; on expansion valve units check system subcooling. Adjust charge as necessary. Note: Refer to the original equipment manufacturer’s superheat and subcooling specifications.
8. Leak check the system and establish preventive maintenance schedule.
A special note: For large-tonnage equipment or unique systems, and or applications, contact ICOR’s Tech-2-Tech department for conversion assistance. Do not use R-422B or any other 400 Series refrigerant in a flooded evaporator application.
International Heating and Cooling Product Distributor Please Guilty
International Heating and Cooling Product Distributor Pleads Guilty and
Sentenced for Illegal Purchase and Sale of Smuggled Ozone-Depleting Refrigerant Gas
Wifredo A. Ferrer, United States Attorney for the Southern
District of Florida, Maureen O’Mara, Special Agent in Charge, United States
Environmental Protection Agency (EPA), Criminal Investigation Division, Atlanta
Area Office, and Alysa D. Erichs, Special Agent in Charge, United States
Immigration and Customs Enforcement’s Homeland Security Investigations
(ICE-HSI), announced today that defendant, FSD Group, LLC a Florida
corporation with its headquarters in Miami, was convicted and sentenced in
connection with the illegal receipt, purchase, and sale of ozone-depleting
refrigerant gas that had been smuggled into the United States contrary to the
Clean Air Act, in violation of Title 18, United States Code, Section 545.
FSD Group pled guilty to a one count Information filed against it before United
States District Court Judge Joan Lenard, for knowingly receiving, buying,
selling and facilitating the transportation, concealment, and sale of
approximately 65,592 kilograms of the ozone-depleting substance
hydrochlorofluorocarbon-22 (“HCFC-22") which had been illegally smuggled
into the United States contrary to the Clean Air Act. HCFC-22 is a widely
used refrigerant for residential heat pump and air-conditioning systems.
Immediately following the guilty plea, FSD Group was sentenced to three years
of probation and ordered to pay a $100,000.00 criminal fine. In addition,
as a special condition of probation, FSD Group was ordered to implement and
enforce a comprehensive Environmental Compliance Plan. FSD Group was also
ordered to forfeit to the United States $180,051.00, which represents proceeds
received as a result of the crime and pay owed duties to the United States
Customs and Border Protection for incorrectly classified merchandise.
Federal law prohibits dealing in merchandise that is imported contrary to
law. The Federal Clean Air Act regulates air pollutants including ozone
depleting substances such as HCFC-22. The Clean Air Act and its
implementing regulations established a schedule to phase out the production and
importation of ozone-depleting substances beginning in 2002, with a complete
ban starting in 2030. To meet its obligations under an international
treaty to reduce its consumption of ozone-depleting substances, the United
States issued baseline allowances for the production and importation of HCFC-22
to individuals and companies. In order to legally import HCFC-22, you
must hold an unexpended consumption allowance.
According to court records, FSD Group which also operates under the name Saez
Distributors, is an international supplier and distributor of merchandise for
heating, ventilation, air conditioning, and refrigerator systems, equipment and
products including ozone-depleting substances. In business for thirty
five years, and itself, an original allowance holder under the Clean Air Act,
FSD had extensive knowledge regarding the Act’s rules and prohibition against
purchasing illegally imported HCFC-22. During the course of the illegal
conduct, in addition to its legal imports, FSD Group made additional purchases
of HCFC-22 from various importers, knowing they did not hold the required
unexpended consumption allowances, totaling approximately 65,592 kilograms, of
restricted HCFC-22, with a fair market value of approximately
$733,096.00.
United
States Attorney Wifredo A. Ferrer stated, “The regulatory program here is
intended to protect us all from the harmful effects associated with depletion
of the earth’s ozone layer. By aggressively supporting the investigative
agencies in their efforts to enforce federal laws that seek to protect our
environment, we are both meeting our country’s commitment and responsibility to
our future generations and the international community.”
EPA SAC Maureen O’Mara said, “HCFC’s deplete the stratospheric
ozone layer, which is critical to life on earth and protecting people from the
harmful effects of ultraviolet radiation, including cancer. EPA will
continue working with ICE and other agencies to combat such criminal conduct,
preventing these dangerous smuggling and distribution operations, and curbing
the world-wide threat of stratospheric ozone depletion. This plea and
sentence, the first of its kind against an allowance holder, sends a strong
message that those who jeopardize public safety in order to make illegal
profits will be vigorously prosecuted and punished.”
“EPA realizes that as HCFCs are phased out domestically, smuggling is likely to
rise, jeopardizing human health and our atmosphere. This is why EPA is working
harder than ever, in cooperation with our federal partners, to seek justice
against those that not only illegally import R-22, but also knowingly purchase
contraband material,” said Drusilla Hufford, Director of EPA’s Stratospheric
Protection Division.
“The unlawful importation of goods poses a significant threat to the national
security, public safety, and in this particular case, the illegal importation
posed a global hazard to our environment,” said Alysa D. Erichs, Special Agent
in Charge of HSI Miami. “We will continue to vigorously investigate those
who are determined to line their pockets with the proceeds of crimes against
the environment.”
This matter and others involving the smuggling and distribution of
ozone-depleting substances are being investigated through a multi-agency
initiative known as Operation Catch-22. Operation Catch-22 has, to date,
including the successful conviction of nearly a dozen individuals and
corporations at every level of the refrigerant gas smuggling and distribution
chain.
Mr.
Ferrer commended the investigative efforts of the EPA, ICE-HSI, the Florida
Department of Environmental Protection, Criminal Investigation Bureau, and the
Miami-Dade Police Department. The case was prosecuted by Special
Assistant U.S. Attorney Jodi A. Mazer.
A copy of this press release may be found on the website of the
United States Attorney's Office for the Southern District of Florida at www.usdoj.gov/usao/fls . Related court documents and
information may be found on the website of the District Court for the Southern
District of Florida at http://www.flsd.uscourts.gov/ or on http://pacer.flsd.uscourts.gov.
Dave Stirpe
Executive Director
Alliance for Responsible Atmospheric Policy
2111 Wilson Blvd., 8th Floor
Arlington, VA 22201
phone: (703) 243-0344
website: www.arap.org
Executive Director
Alliance for Responsible Atmospheric Policy
2111 Wilson Blvd., 8th Floor
Arlington, VA 22201
phone: (703) 243-0344
website: www.arap.org
Labels:
a-gas remtec,
HCFC,
hcfc 22,
I want to sell 22,
r-22,
r22
Tuesday, February 12, 2013
AHRI Responds to Counterfeit Refrigerant Reports, Offers Guidance to Detect and Avoid
|
|
|
|
Tuesday, January 29, 2013
DuPont Wins Counterfeit Case
January 21, 2013
WILMINGTON, Del. — DuPont Refrigerants recently finished a two-year effort to investigate counterfeit activity of DuPont refrigerant brands in Quzhou City, Zhejiang Province, China.
In 2009, a distributor alerted DuPont to potential counterfeiting of DuPont Suva and DuPont Freon brands. The information they provided led Dupont to suspect counterfeiting activity of Quzhouzhou Fuming Co. Ltd., in Quzhou City. With assistance from a local law firm, DuPont requested that local authorities conduct a raid of the suspected counterfeit facility. A raid action in late September 2011 resulted in the seizure of 1,500 empty refrigerant cylinders with DuPont Suva and Freon packaging, 1,000 counterfeit labels, and 1,000 counterfeit DuPont Freon R-22 cylinders.
After the raid, DuPont issued cease-and-desist letters, however, the company did not respond to the request and continued to sell the counterfeit refrigerants. In response, DuPont filed legal action against those responsible.
A court case was undertaken in China and a judicial settlement was reached in August 2012. The defendant was required to pay the equivalent of $39,400 to the Chinese government and $32,000 in damages and court costs to DuPont. The company is under a permanent injunction to not sell DuPont refrigerants or engage in counterfeit activities involving DuPont trademarks going forward. As part of the sentence, the judge also required the company to post a formal public apology in two Chinese newspapers.
“We will continue to combat counterfeiting of DuPont refrigerants, using assistance from local law enforcement, government officials, and customs organizations,” said Greg Rubin, DuPont global business manager. “This effort is ongoing and this case was an excellent example of cross-regional work between DuPont and our distributors. This is a collaborative effort. We can’t combat counterfeiting alone.”
Publication date: 1/21/2013 AHRI THE NEWS
Wednesday, January 9, 2013
EPA Issues Temporary R-22 Waiver
This afternoon the Environmental Protection Agency (EPA)
issued a No Action Assurance Letter to the manufacturers and importers
of R-22, which now allows for the production and importation of the
refrigerant. Because the regulation responsible for governing the allocation of
R-22 has not been finalized, manufacturers and importers were unable to make or
bring new product into the United States (effective January 1, 2013), until
this letter was received or the rule was finalized. This No Action
Assurance Letter is valid until December 31, 2013 or until the R-22
Allocation rule is finalized by the EPA, whichever comes first.
It had been anticipated that the No Action Assurance Letter would limit importation and production of R-22 to approximately 45 million pounds in 2013, as proposed in the Allocation rule, however the letter issued today allows for roughly 39 million pounds to be produced or imported. This difference of approximately 6 million pounds would allow for potential recoupment of lost allocation rights by Arkema and Solvay, who were found to have been improperly denied allocation rights in a previous period.
What Distributors Need to Know Today: Your suppliers can once again produce and import R-22, albeit at levels slightly lower than had been anticipated. An additional 6 million pounds of R-22 is likely to be allowed upon completion of the Allocation rule (approximately April 1, 2013), although it is not yet clear how those rights would be divided amongst companies. HARDI will continue to update members as developments occur.
Wednesday, January 2, 2013
Illegal R22 importer gets six months
Source: ACR-news.com - http://www.ACR-news.com/USA: The Florida man who pled guilty to knowingly importing approximately 15,640kg of illegal R22 into America has been sentenced to six months in prison, and six months under electronically monitored home-confinement, followed by 18 months of supervised release. The Miami Court also imposed a criminal fine of $3,000.
Norberto Guada pled guilty in October to a single count of a multiple-count indictment which had been brought against him and co-defendant Jorge G Murillo.
Guada was hired as a salesman in February 2007 by a company known as Lateral Investments LLC (Lateral). Lateral was a Florida corporation, engaged in, among other things, importing merchandise, including refrigerant gas. Between June and August 2007, Lateral illegally smuggled large quantities of R22 into the United States to sell on the black market. At no time did Lateral or its principals hold unexpended consumption allowances that would have allowed them to legally import the R22.
During 2007, Lateral illegally imported approximately 278,256kg or 20,460 cylinders of restricted R22, with a market value of $1,438,270. Guada was tasked with selling the refrigerant to businesses in the South Florida area. As part of his agreement in this matter, Guada specifically admitted to his knowing involvement in the importation and sale, contrary to law, of 15,640kg of R22 on August 10, 2007.
Click here for original article: http://www.acr-news.com/news/news.asp?id=3134&title=Illegal+R22+importer+gets+six+months